You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15256
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFreitas Júnior, Amilcar C.-
dc.contributor.authorRocha, Eduardo Passos-
dc.contributor.authorBonfante, Estevam A.-
dc.contributor.authorAlmeida, Erika O.-
dc.contributor.authorAnchieta, Rodolfo B.-
dc.contributor.authorMartini, Ana P.-
dc.contributor.authorAssunção, Wirley Goncalves-
dc.contributor.authorSilva, Nelson R. F. A.-
dc.contributor.authorCoelho, Paulo G.-
dc.date.accessioned2013-09-30T18:30:01Z-
dc.date.accessioned2014-05-20T13:43:41Z-
dc.date.accessioned2016-10-25T16:58:12Z-
dc.date.available2013-09-30T18:30:01Z-
dc.date.available2014-05-20T13:43:41Z-
dc.date.available2016-10-25T16:58:12Z-
dc.date.issued2012-10-01-
dc.identifierhttp://dx.doi.org/10.1016/j.dental.2012.05.004-
dc.identifier.citationDental Materials. Oxford: Elsevier B.V., v. 28, n. 10, p. E218-E228, 2012.-
dc.identifier.issn0109-5641-
dc.identifier.urihttp://hdl.handle.net/11449/15256-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15256-
dc.description.abstractObjectives. The aim of this study was to assess the effect of abutment's diameter shifting on reliability and stress distribution within the implant-abutment connection for internal and external hexagon implants. The postulated hypothesis was that platform-switched implants would result in increased stress concentration within the implant-abutment connection, leading to the systems' lower reliability.Methods. Eighty-four implants were divided in four groups (n = 21): REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). The corresponding abutments were screwed to the implants and standardized maxillary central incisor metal crowns were cemented and subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability were calculated. Four finite element models reproducing the characteristics of specimens used in laboratory testing were created. The models were full constrained on the bottom and lateral surface of the cylinder of acrylic resin and one 30 degrees off-axis load (300 N) was applied on the lingual side of the crown (close to the incisal edge) in order to evaluate the stress distribution (s(vM)) within the implant-abutment complex.Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The higher levels of sigma(vM) within the implant-abutment connection observed for platform-switched implants (groups SWT-EH and SWT-IH) were in agreement with the lower reliability observed for the external hex implants, but not for the internal hex implants. The reliability 90% confidence intervals (50,000 cycles at 300 N) were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), for the SWT-EH, REG-EH, SWT-IH, and REH-IH, respectively.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipMarotta Dental Studio (Farmingdale, NY, USA)-
dc.description.sponsorshipSIN implants (São Paulo, SP, Brazil)-
dc.format.extentE218-E228-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectDental implantsen
dc.subjectPlatform switchingen
dc.subjectBiomechanicsen
dc.subjectReliabilityen
dc.subjectFinite element analysisen
dc.titleBiomechanical evaluation of internal and external hexagon platform switched implant-abutment connections: An in vitro laboratory and three-dimensional finite element analysisen
dc.typeoutro-
dc.contributor.institutionNYU-
dc.contributor.institutionUniv Potiguar-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUnigranrio Univ-
dc.description.affiliationNYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA-
dc.description.affiliationUniv Potiguar, Sch Hlth Sci, Postgrad Program Dent, Natal, RN, Brazil-
dc.description.affiliationSão Paulo State Univ, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil-
dc.description.affiliationUnigranrio Univ, Sch Hlth Sci, Postgrad Program Dent, Duque de Caxias, RJ, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil-
dc.description.sponsorshipIdCNPq: 141870/2008-7-
dc.identifier.doi10.1016/j.dental.2012.05.004-
dc.identifier.wosWOS:000308469300004-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofDental Materials-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.