You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15290
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVerri, Fellippo Ramos-
dc.contributor.authorPellizzer, Eduardo Piza-
dc.contributor.authorPereira, Joao Antonio-
dc.contributor.authorZuim, Paulo Renato Junqueira-
dc.contributor.authorSantiago Junior, Joel Ferreira-
dc.date.accessioned2013-09-30T18:30:08Z-
dc.date.accessioned2014-05-20T13:43:45Z-
dc.date.accessioned2016-10-25T16:58:15Z-
dc.date.available2013-09-30T18:30:08Z-
dc.date.available2014-05-20T13:43:45Z-
dc.date.available2016-10-25T16:58:15Z-
dc.date.issued2011-06-01-
dc.identifierhttp://dx.doi.org/10.1097/ID.0b013e3182166927-
dc.identifier.citationImplant Dentistry. Philadelphia: Lippincott Williams & Wilkins, v. 20, n. 3, p. 192-+, 2011.-
dc.identifier.issn1056-6163-
dc.identifier.urihttp://hdl.handle.net/11449/15290-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15290-
dc.description.abstractPurpose: This study evaluated the influence of distal extension removable partial denture associated with implant in cases of different bone level of abutment tooth, using 2D finite element analysis.Materials and Methods: Eight hemiarch models were simulated: model A-presenting tooth 33 and distal extension removable partial denture replacing others teeth, using distal rest connection and no bone lost; model B-similar to model A but presenting distal guide plate connection; model C-similar to model A but presenting osseointegrated implant with ERA retention system associated under prosthetic base; model D-similar to model B but presenting osseointegrated implant as described in model C; models E, F, G, and H were similar to models A, B, C, and D but presenting reduced periodontal support around tooth 33. Using ANSYS 9.0 software, the models were loaded vertically with 50 N on each cusp tip. For results, von Mises Stress Maps were plotted.Results: Maximum stress value was encountered in model G (201.023 MPa). Stress distribution was concentrated on implant and retention system. The implant/removable partial denture association decreases stress levels on alveolar mucosa for all models.Conclusions: Use of implant and ERA system decreased stress concentrations on supporting structures in all models. Use of distal guide plate decreased stress levels on abutment tooth and cortical and trabecular bone. Tooth apex of models with reduced periodontal support presented increased stress when using distal rest. (Implant Dent 2011;20:192-201)en
dc.format.extent192-+-
dc.language.isoeng-
dc.publisherLippincott Williams & Wilkins-
dc.sourceWeb of Science-
dc.subjectbiomechanicsen
dc.subjectfinite element analysisen
dc.subjectremovable partial dentureen
dc.subjectdental implanten
dc.subjectdental stress analysisen
dc.titleEvaluation of Bone Insertion Level of Support Teeth in Class I Mandibular Removable Partial Denture Associated With an Osseointegrated Implant: A Study Using Finite Element Analysisen
dc.typeoutro-
dc.contributor.institutionSch Dent Adamantina-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSch Dent Adamantina, Dept Dent, São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista, Engn Fac Ilha Solteira, Dept Mech Enginnering, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Engn Fac Ilha Solteira, Dept Mech Enginnering, São Paulo, Brazil-
dc.identifier.doi10.1097/ID.0b013e3182166927-
dc.identifier.wosWOS:000291004700007-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofImplant Dentistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.