Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/15325
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorPellizzer, Eduardo Piza-
dc.contributor.authorVerri, Fellippo Ramos-
dc.contributor.authorFalcon-Antenucci, Rosse Mary-
dc.contributor.authorGoiato, Marcelo Coelho-
dc.contributor.authorGennari Filho, Humberto-
dc.date.accessioned2013-09-30T18:30:17Z-
dc.date.accessioned2014-05-20T13:43:49Z-
dc.date.accessioned2016-10-25T16:58:19Z-
dc.date.available2013-09-30T18:30:17Z-
dc.date.available2014-05-20T13:43:49Z-
dc.date.available2016-10-25T16:58:19Z-
dc.date.issued2010-05-01-
dc.identifierhttp://dx.doi.org/10.1097/SCS.0b013e3181d8098a-
dc.identifier.citationJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 3, p. 727-734, 2010.-
dc.identifier.issn1049-2275-
dc.identifier.urihttp://hdl.handle.net/11449/15325-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15325-
dc.description.abstractThe aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.en
dc.format.extent727-734-
dc.language.isoeng-
dc.publisherLippincott Williams & Wilkins-
dc.sourceWeb of Science-
dc.subjectDental implanten
dc.subjectretention systemsen
dc.subjectremovable partial dentureen
dc.subjectfinite element analysesen
dc.titleEvaluation of Different Retention Systems on a Distal Extension Removable Partial Denture Associated With an Osseointegrated Implanten
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFac Integrated Adamantina-
dc.description.affiliationSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.description.affiliationFac Integrated Adamantina, São Paulo, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Aracatuba Sch Dent, Dept Dent Mat & Prosthodont, São Paulo, Brazil-
dc.identifier.doi10.1097/SCS.0b013e3181d8098a-
dc.identifier.wosWOS:000278102200022-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Craniofacial Surgery-
dc.identifier.orcid0000-0002-3800-3050pt
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.