Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/15346
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guiotti, Aimée Maria | - |
dc.contributor.author | Goiato, Marcelo Coelho | - |
dc.contributor.author | Santos, Daniela Micheline dos | - |
dc.date.accessioned | 2013-09-30T18:30:21Z | - |
dc.date.accessioned | 2014-05-20T13:43:52Z | - |
dc.date.accessioned | 2016-10-25T16:58:22Z | - |
dc.date.available | 2013-09-30T18:30:21Z | - |
dc.date.available | 2014-05-20T13:43:52Z | - |
dc.date.available | 2016-10-25T16:58:22Z | - |
dc.date.issued | 2010-03-01 | - |
dc.identifier | http://dx.doi.org/10.1097/SCS.0b013e3181cf5fa4 | - |
dc.identifier.citation | Journal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 2, p. 323-327, 2010. | - |
dc.identifier.issn | 1049-2275 | - |
dc.identifier.uri | http://hdl.handle.net/11449/15346 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/15346 | - |
dc.description.abstract | The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the Shore A hardness of silicone used for fabrication of facial prostheses, Silastic MDX4-4210, according to the influence of storage period, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and divided in 3 groups: colorless, pigmented with makeup, and pigmented with iron oxide. Analysis of results was assessed on a Shore A hardness meter immediately, 6 months, and 1 year after fabrication of specimens, following the guidelines of the American Society for Testing and Materials. The hardness values were statistically analyzed by the Tukey test. The silicone exhibited an increase in hardness with time. However, the hardness was stable from 6 months to 1 year. It was concluded that the silicone is within the values of Shore A hardness reported in the literature, regardless of the storage period, pigmentation, and chemical disinfection. | en |
dc.format.extent | 323-327 | - |
dc.language.iso | eng | - |
dc.publisher | Lippincott Williams & Wilkins | - |
dc.source | Web of Science | - |
dc.subject | Maxillofacial prosthesis | en |
dc.subject | silicones | en |
dc.subject | disinfection | en |
dc.subject | hardness | en |
dc.title | Evaluation of the Shore A Hardness of Silicone for Facial Prosthesis as to the Effect of Storage Period and Chemical Disinfection | en |
dc.type | outro | - |
dc.contributor.institution | Fac Integradas Santa Fe do Sul | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Fac Integradas Santa Fe do Sul, Santa Fe do Sul Dent Sch, Dept Dent Mat & Prosthodont, Santa Fe do Sul, Brazil | - |
dc.description.affiliation | Univ State São Paulo, Dept Dent Mat & Prosthesis, São Paulo, Brazil | - |
dc.identifier.doi | 10.1097/SCS.0b013e3181cf5fa4 | - |
dc.identifier.wos | WOS:000276073200008 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Craniofacial Surgery | - |
dc.identifier.orcid | 0000-0002-3800-3050 | pt |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.