You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/15687
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPredebon, Juliane Ceolin-
dc.contributor.authorLima, Luciana Monti-
dc.contributor.authorFlorio, Flavia Martao-
dc.contributor.authorSantos-Pinto, Lourdes Aparecida Martins dos-
dc.contributor.authorBasting, Roberta Tarkany-
dc.date.accessioned2014-02-26T16:59:48Z-
dc.date.accessioned2014-05-20T13:44:43Z-
dc.date.accessioned2016-10-25T16:58:53Z-
dc.date.available2014-02-26T16:59:48Z-
dc.date.available2014-05-20T13:44:43Z-
dc.date.available2016-10-25T16:58:53Z-
dc.date.issued2007-10-01-
dc.identifierhttp://dx.doi.org/10.1007/s10853-007-1766-8-
dc.identifier.citationJournal of Materials Science. New York: Springer, v. 42, n. 20, p. 8454-8460, 2007.-
dc.identifier.issn0022-2461-
dc.identifier.urihttp://hdl.handle.net/11449/15687-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15687-
dc.description.abstractThe aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.en
dc.format.extent8454-8460-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.titleMicromorphologic assessment of CVD (chemical vapor deposition) and conventional diamond tips and their cutting effectivenessen
dc.typeoutro-
dc.contributor.institutionDent Res Ctr Sao Leopoldo Mand-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionSch Dent-
dc.contributor.institutionFac Odontol-
dc.contributor.institutionCtr Pesquisas Odontol Sao Leopoldo Mand-
dc.description.affiliationDent Res Ctr Sao Leopoldo Mand, Campinas, SP, Brazil-
dc.description.affiliationUNESP, Dent Sch Araraquara, Araraquara, SP, Brazil-
dc.description.affiliationSch Dent, Campinas, SP, Brazil-
dc.description.affiliationUNESP, Dent Sch Araraquara, Pediat Clin Dept, Araraquara, SP, Brazil-
dc.description.affiliationFac Odontol, Dept Odontol Restauradora Dent, BR-13045 Campinas, SP, Brazil-
dc.description.affiliationCtr Pesquisas Odontol Sao Leopoldo Mand, BR-13045 Campinas, SP, Brazil-
dc.description.affiliationUnespUNESP, Dent Sch Araraquara, Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Dent Sch Araraquara, Pediat Clin Dept, Araraquara, SP, Brazil-
dc.identifier.doi10.1007/s10853-007-1766-8-
dc.identifier.wosWOS:000248764500010-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Materials Science-
dc.identifier.orcid0000-0003-2386-842X-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.