Utilize este identificador para citar ou criar um link para este item:
http://acervodigital.unesp.br/handle/11449/15731
Registro de metadados completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Diniz, Michele Baffi | - |
dc.contributor.author | Rodrigues, Jonas de Almeida | - |
dc.contributor.author | de Paula, Andreia Bolzan | - |
dc.contributor.author | Loiola Cordeiro, Rita de Cassia | - |
dc.date.accessioned | 2013-09-30T18:31:17Z | - |
dc.date.accessioned | 2014-05-20T13:44:50Z | - |
dc.date.accessioned | 2016-10-25T16:58:58Z | - |
dc.date.available | 2013-09-30T18:31:17Z | - |
dc.date.available | 2014-05-20T13:44:50Z | - |
dc.date.available | 2016-10-25T16:58:58Z | - |
dc.date.issued | 2009-05-01 | - |
dc.identifier | http://dx.doi.org/10.1007/s10103-008-0547-1 | - |
dc.identifier.citation | Lasers In Medical Science. Artington: Springer London Ltd, v. 24, n. 3, p. 295-300, 2009. | - |
dc.identifier.issn | 0268-8921 | - |
dc.identifier.uri | http://hdl.handle.net/11449/15731 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/15731 | - |
dc.description.abstract | The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries. | en |
dc.format.extent | 295-300 | - |
dc.language.iso | eng | - |
dc.publisher | Springer London Ltd | - |
dc.source | Web of Science | - |
dc.subject | Occlusal caries | en |
dc.subject | DIAGNOdent | en |
dc.subject | Laser fluorescence | en |
dc.subject | In vivo | en |
dc.title | In vivo evaluation of laser fluorescence performance using different cut-off limits for occlusal caries detection | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | - |
dc.description.affiliation | São Paulo State Univ, UNESP, Dept Pediat Dent, Araraquara Sch Dent, BR-14801903 Araraquara, SP, Brazil | - |
dc.description.affiliation | Univ Estadual Campinas, Dept Dent Mat, Sch Dent Piracicaba, UNICAMP, BR-13414903 Piracicaba, SP, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Dept Pediat Dent, Araraquara Sch Dent, BR-14801903 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1007/s10103-008-0547-1 | - |
dc.identifier.wos | WOS:000265499300001 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Lasers in Medical Science | - |
Aparece nas coleções: | Artigos, TCCs, Teses e Dissertações da Unesp |
Não há nenhum arquivo associado com este item.
Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.