Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/15927
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Correa, Cassia B. | - |
dc.contributor.author | Ramos, Nuno V. | - |
dc.contributor.author | Monteiro, Jaime | - |
dc.contributor.author | Vaz, Luis Geraldo | - |
dc.contributor.author | Vaz, Mario A. P. | - |
dc.date.accessioned | 2013-09-30T18:31:39Z | - |
dc.date.accessioned | 2014-05-20T13:45:18Z | - |
dc.date.available | 2013-09-30T18:31:39Z | - |
dc.date.available | 2014-05-20T13:45:18Z | - |
dc.date.issued | 2012-01-01 | - |
dc.identifier | http://dx.doi.org/10.1117/12.978232 | - |
dc.identifier.citation | Speckle 2012: V International Conference on Speckle Metrology. Bellingham: Spie-int Soc Optical Engineering, v. 8413, p. 5, 2012. | - |
dc.identifier.issn | 0277-786X | - |
dc.identifier.uri | http://hdl.handle.net/11449/15927 | - |
dc.description.abstract | The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure. | en |
dc.format.extent | 5 | - |
dc.language.iso | eng | - |
dc.publisher | Spie - Int Soc Optical Engineering | - |
dc.source | Web of Science | - |
dc.subject | Biomechanics | en |
dc.subject | Prostheses and Implants | en |
dc.title | Analysis of mechanical behavior of implant-supported prostheses in the anterior maxilla: analysis by speckle pattern interferometry | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista UNESP, Sch Dent Araraquara, Dept Diag & Surg, Jaboticabal, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista UNESP, Sch Dent Araraquara, Dept Diag & Surg, Jaboticabal, SP, Brazil | - |
dc.identifier.doi | 10.1117/12.978232 | - |
dc.identifier.wos | WOS:000311899100045 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Speckle 2012: V International Conference on Speckle Metrology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.