Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/15933
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorMarcantonio, Elcio-
dc.contributor.authorDela Coleta, Roberto-
dc.contributor.authorSpin-Neto, Rubens-
dc.contributor.authorMarcantonio, Elcio-
dc.contributor.authorPizzol, Karina Eiras Dela Coleta-
dc.contributor.authorBoeck, Eloisa Marcantonio-
dc.date.accessioned2013-09-30T18:31:41Z-
dc.date.accessioned2014-05-20T13:45:19Z-
dc.date.accessioned2016-10-25T16:59:22Z-
dc.date.available2013-09-30T18:31:41Z-
dc.date.available2014-05-20T13:45:19Z-
dc.date.available2016-10-25T16:59:22Z-
dc.date.issued2008-11-01-
dc.identifierhttp://dx.doi.org/10.1016/j.joms.2008.06.031-
dc.identifier.citationJournal of Oral and Maxillofacial Surgery. Philadelphia: W B Saunders Co-elsevier Inc, v. 66, n. 11, p. 2339-2344, 2008.-
dc.identifier.issn0278-2391-
dc.identifier.urihttp://hdl.handle.net/11449/15933-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/15933-
dc.description.abstractOsteodistraction is a clinical reality available for the resolution of bone deficiencies before dental implant placement or in cases where the existing implants are at the wrong position. The objective of this study is to suggest a new possibility for bone distraction, based on tooth-implant bone distractors, in areas were there is the need for extensive alveolar bone recovery, with installed dental implants. This technique presented good results associated with its simplicity and low cost, making it a viable clinical solution for bone tissue augmentation. Although its use is recent, the suggested technique shows the potential to become used widely in attempts to achieve bone-height augmentation, primarily when dental implants are installed and osteointegrated already. (C) 2008 American Association of Oral and Maxillofacial Surgeonsen
dc.format.extent2339-2344-
dc.language.isoeng-
dc.publisherW B Saunders Co-elsevier Inc-
dc.sourceWeb of Science-
dc.titleUse of a Tooth-Implant Supported Bone Distractor in Oral Rehabilitation: Description of a Personalized Techniqueen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUNIARA Araraquara Univ-
dc.contributor.institutionUNIARARAS Araras-
dc.description.affiliationUNESP, Dept Periodontol, Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUNESP, Dept Buccomaxillofacial Surg, Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUNIARA Araraquara Univ, Dept Orthodont, Araraquara Dent Sch, São Paulo, Brazil-
dc.description.affiliationUNIARARAS Araras, Ctr Univ Herminio Ometto, Dept Orthodont, São Paulo, Brazil-
dc.description.affiliationUnespUNESP, Dept Periodontol, Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP, Dept Buccomaxillofacial Surg, Araraquara Dent Sch, BR-14801903 Araraquara, SP, Brazil-
dc.identifier.doi10.1016/j.joms.2008.06.031-
dc.identifier.wosWOS:000260606700024-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Oral and Maxillofacial Surgery-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.