Você está no menu de acessibilidade

Utilize este identificador para citar ou criar um link para este item: http://acervodigital.unesp.br/handle/11449/16036
Registro de metadados completo
Campo DCValorIdioma
dc.contributor.authorTanomaru-Filho, M.-
dc.contributor.authorJorge, E. G.-
dc.contributor.authorTanomaru, Juliane Maria Guerreiro-
dc.contributor.authorGonçalves, Marcelo-
dc.date.accessioned2014-05-20T13:45:33Z-
dc.date.accessioned2016-10-25T16:59:35Z-
dc.date.available2014-05-20T13:45:33Z-
dc.date.available2016-10-25T16:59:35Z-
dc.date.issued2008-01-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1365-2591.2007.01309.x-
dc.identifier.citationInternational Endodontic Journal. Oxford: Blackwell Publishing, v. 41, n. 1, p. 50-53, 2008.-
dc.identifier.issn0143-2885-
dc.identifier.urihttp://hdl.handle.net/11449/16036-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16036-
dc.description.abstractAim To evaluate the radiopacity of calcium hydroxide-based root canal sealers (Acroseal, Sealapex and Sealer 26), a glass-ionomer-based sealer (Activ GP Sealer) and a zinc oxide and eugenol-based sealer (Intrafill).Methodology Five disc-shaped specimens (10 x 1 mm) were fabricated from each material, according to the International Organization for Standardization (ISO) 6876/2001 standard. After setting of the materials, radiographs were taken using occlusal films and a graduated aluminum step-wedge varying from 2 to 16 mm in thickness. The dental X-ray unit (GE1000) was set at 50 Kvp, 10 mA, 18 pulses s(-1) and distance of 33.5 cm. The radiographs were digitized and the radiopacity compared with that of the aluminum step-wedge, using WIXWIN-2000 software (Gendex). Data (mm Al) were submitted to ANOVA and Tukey test.Results Intrafill was the most radiopaque material (7.67 mm Al) followed by Sealer 26 (6.33 mm Al), Sealapex (6.05 mm Al) and Acroseal (4.03 mm Al). Activ GP was the least radiopaque material (1.95 mm Al, P < 0.05).Conclusions The sealers evaluated in this study had different radiopacities. However, except for the glass-ionomer-based sealer, all materials had radiopacity values above the minimum recommended by the ISO standard.en
dc.format.extent50-53-
dc.language.isoeng-
dc.publisherBlackwell Publishing-
dc.sourceWeb of Science-
dc.subjectradiologyen
dc.subjectradiopacityen
dc.subjectroot canal filling materialsen
dc.titleEvaluation of the radiopacity of calcium hydroxide- and glass-ionomer-based root canal sealersen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, Dept Restorat Dent, São Paulo, Brazil-
dc.description.affiliationUniv Estadual Paulista, Araraquara Dent Sch, Dept Radiol, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Restorat Dent, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Araraquara Dent Sch, Dept Radiol, São Paulo, Brazil-
dc.identifier.doi10.1111/j.1365-2591.2007.01309.x-
dc.identifier.wosWOS:000252260800005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Endodontic Journal-
Aparece nas coleções:Artigos, TCCs, Teses e Dissertações da Unesp

Não há nenhum arquivo associado com este item.
 

Itens do Acervo digital da UNESP são protegidos por direitos autorais reservados a menos que seja expresso o contrário.