You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16389
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGonçalves, Andréa-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorVergani, Carlos Eduardo-
dc.contributor.authorGiampaolo, Eunice Teresinha-
dc.contributor.authorPavarina, Ana Claudia-
dc.date.accessioned2014-05-20T13:46:20Z-
dc.date.accessioned2016-10-25T17:00:06Z-
dc.date.available2014-05-20T13:46:20Z-
dc.date.available2016-10-25T17:00:06Z-
dc.date.issued2007-01-01-
dc.identifierhttp://dx.doi.org/10.1080/00218460701198610-
dc.identifier.citationJournal of Adhesion. Abingdon: Taylor & Francis Ltd, v. 83, n. 1-3, p. 139-150, 2007.-
dc.identifier.issn0021-8464-
dc.identifier.urihttp://hdl.handle.net/11449/16389-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16389-
dc.description.abstractCylinders (3.5 x 5.0 mm) of the reline resins Kooliner (K), New Truliner (N), Tokuso Rebase Fast (T), and Ufi Gel Hard (U) were bonded to cylinders (20 x 20 mm) of the denture base resin Lucitone 550 (L), and samples were divided into two controls and four test groups (n = 8). Shear tests (0.5 mm/min) were performed after polymerization or immersion in water (37 degrees C) for 7 days (controls); two or seven cycles of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min). Statistical analyses (alpha = 0.05) revealed that two cycles of microwave and chemical disinfection increased the mean bond strengths of materials T (9.08 to 12.93 MPa) and L (18.89 to 23.02 MPa). For resin L, seven cycles of chemical (15.72 MPa) and microwave (17.82 MPa) disinfection decreased the shear bond strength compared with the respective control (21.74 MPa). Resins U (13.12 MPa), K (8.44 MPa), and N (7.98 MPa) remained unaffected.en
dc.format.extent139-150-
dc.language.isoeng-
dc.publisherTaylor & Francis Ltd-
dc.sourceWeb of Science-
dc.subjectbond strengthpt
dc.subjectdental polymerspt
dc.subjectmicrowave irradiationpt
dc.titleEffect of disinfection on adhesion of reline polymersen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionPiaui Fed Univ-
dc.description.affiliationUniv Estadual Paulista, Fac Odontol Araraquara, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil-
dc.description.affiliationPiaui Fed Univ, Dept Restorat Dent, Teresina, Piaui, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Fac Odontol Araraquara, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil-
dc.identifier.doi10.1080/00218460701198610-
dc.identifier.wosWOS:000245242400010-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Adhesion-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.