Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16389
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gonçalves, Andréa | - |
dc.contributor.author | Machado, Ana Lucia | - |
dc.contributor.author | Vergani, Carlos Eduardo | - |
dc.contributor.author | Giampaolo, Eunice Teresinha | - |
dc.contributor.author | Pavarina, Ana Claudia | - |
dc.date.accessioned | 2014-05-20T13:46:20Z | - |
dc.date.accessioned | 2016-10-25T17:00:06Z | - |
dc.date.available | 2014-05-20T13:46:20Z | - |
dc.date.available | 2016-10-25T17:00:06Z | - |
dc.date.issued | 2007-01-01 | - |
dc.identifier | http://dx.doi.org/10.1080/00218460701198610 | - |
dc.identifier.citation | Journal of Adhesion. Abingdon: Taylor & Francis Ltd, v. 83, n. 1-3, p. 139-150, 2007. | - |
dc.identifier.issn | 0021-8464 | - |
dc.identifier.uri | http://hdl.handle.net/11449/16389 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/16389 | - |
dc.description.abstract | Cylinders (3.5 x 5.0 mm) of the reline resins Kooliner (K), New Truliner (N), Tokuso Rebase Fast (T), and Ufi Gel Hard (U) were bonded to cylinders (20 x 20 mm) of the denture base resin Lucitone 550 (L), and samples were divided into two controls and four test groups (n = 8). Shear tests (0.5 mm/min) were performed after polymerization or immersion in water (37 degrees C) for 7 days (controls); two or seven cycles of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min). Statistical analyses (alpha = 0.05) revealed that two cycles of microwave and chemical disinfection increased the mean bond strengths of materials T (9.08 to 12.93 MPa) and L (18.89 to 23.02 MPa). For resin L, seven cycles of chemical (15.72 MPa) and microwave (17.82 MPa) disinfection decreased the shear bond strength compared with the respective control (21.74 MPa). Resins U (13.12 MPa), K (8.44 MPa), and N (7.98 MPa) remained unaffected. | en |
dc.format.extent | 139-150 | - |
dc.language.iso | eng | - |
dc.publisher | Taylor & Francis Ltd | - |
dc.source | Web of Science | - |
dc.subject | bond strength | pt |
dc.subject | dental polymers | pt |
dc.subject | microwave irradiation | pt |
dc.title | Effect of disinfection on adhesion of reline polymers | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Piaui Fed Univ | - |
dc.description.affiliation | Univ Estadual Paulista, Fac Odontol Araraquara, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil | - |
dc.description.affiliation | Piaui Fed Univ, Dept Restorat Dent, Teresina, Piaui, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Odontol Araraquara, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 São Paulo, Brazil | - |
dc.identifier.doi | 10.1080/00218460701198610 | - |
dc.identifier.wos | WOS:000245242400010 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Journal of Adhesion | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.