You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16455
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUrban, Vanessa M.-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorAlves, Marines O.-
dc.contributor.authorMaciel, Adeilton P.-
dc.contributor.authorVergani, Carlos Eduardo-
dc.contributor.authorLeite, Edson R.-
dc.date.accessioned2014-05-20T13:46:28Z-
dc.date.accessioned2016-10-25T17:00:12Z-
dc.date.available2014-05-20T13:46:28Z-
dc.date.available2016-10-25T17:00:12Z-
dc.date.issued2010-09-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2009.00312.x-
dc.identifier.citationGerodontology. Malden: Wiley-blackwell, v. 27, n. 3, p. 230-235, 2010.-
dc.identifier.issn0734-0664-
dc.identifier.urihttp://hdl.handle.net/11449/16455-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16455-
dc.description.abstractObjective:This study evaluated the effect of post-polymerisation treatments on the glass transition temperature (T(g)) of five hard chairside reline materials (Duraliner II-D, Kooliner-K, New Truliner-N, Ufi Gel hard-U and Tokuso Rebase Fast-T).Materials and methods:Specimens (10 x 10 x 1 mm) were made following the manufacturers' instructions and divided into three groups (n = 5). Control group specimens were left untreated. Specimens from the microwave group were irradiated with pre-determined power/time combinations, and specimens from the water-bath group were immersed in hot water at 55 degrees C for 10 min. Glass transition (degrees C) was performed by differential scanning calorimetry. Data were analysed using anova, followed by post hoc Tukey's test (alpha = 0.05).Results:Both post-polymerisation treatments promoted a significant (p < 0.05) increase in the T(g) of reline material K. Materials K, D and N showed the lowest T(g) (p < 0.05). No significant difference between T and U specimens was observed.Conclusion:Post-polymerisation treatments improved the glass transition of material Kooliner, with the effect being more pronounced for microwave irradiation.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent230-235-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectacrylic resinen
dc.subjectglass transition temperatureen
dc.subjectdifferential scanning calorimetryen
dc.subjectpost-polymerisation treatmenten
dc.titleGlass transition temperature of hard chairside reline materials after post-polymerisation treatmentsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual de Ponta Grossa (UEPG)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.description.affiliationPonta Grossa State Univ UEPG, Dept Dent, Ponta Grossa, PR, Brazil-
dc.description.affiliationSão Paulo State Univ UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil-
dc.description.affiliationSão Carlos Fed Univ UFSCar, Interdisciplinary Lab Eletrochem & Ceram, Dept Chem, São Carlos, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 02/01405-0-
dc.description.sponsorshipIdFAPESP: 02/06919-1-
dc.identifier.doi10.1111/j.1741-2358.2009.00312.x-
dc.identifier.wosWOS:000281209300013-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofGerodontology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.