Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16455
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Urban, Vanessa M. | - |
dc.contributor.author | Machado, Ana Lucia | - |
dc.contributor.author | Alves, Marines O. | - |
dc.contributor.author | Maciel, Adeilton P. | - |
dc.contributor.author | Vergani, Carlos Eduardo | - |
dc.contributor.author | Leite, Edson R. | - |
dc.date.accessioned | 2014-05-20T13:46:28Z | - |
dc.date.accessioned | 2016-10-25T17:00:12Z | - |
dc.date.available | 2014-05-20T13:46:28Z | - |
dc.date.available | 2016-10-25T17:00:12Z | - |
dc.date.issued | 2010-09-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1741-2358.2009.00312.x | - |
dc.identifier.citation | Gerodontology. Malden: Wiley-blackwell, v. 27, n. 3, p. 230-235, 2010. | - |
dc.identifier.issn | 0734-0664 | - |
dc.identifier.uri | http://hdl.handle.net/11449/16455 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/16455 | - |
dc.description.abstract | Objective:This study evaluated the effect of post-polymerisation treatments on the glass transition temperature (T(g)) of five hard chairside reline materials (Duraliner II-D, Kooliner-K, New Truliner-N, Ufi Gel hard-U and Tokuso Rebase Fast-T).Materials and methods:Specimens (10 x 10 x 1 mm) were made following the manufacturers' instructions and divided into three groups (n = 5). Control group specimens were left untreated. Specimens from the microwave group were irradiated with pre-determined power/time combinations, and specimens from the water-bath group were immersed in hot water at 55 degrees C for 10 min. Glass transition (degrees C) was performed by differential scanning calorimetry. Data were analysed using anova, followed by post hoc Tukey's test (alpha = 0.05).Results:Both post-polymerisation treatments promoted a significant (p < 0.05) increase in the T(g) of reline material K. Materials K, D and N showed the lowest T(g) (p < 0.05). No significant difference between T and U specimens was observed.Conclusion:Post-polymerisation treatments improved the glass transition of material Kooliner, with the effect being more pronounced for microwave irradiation. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.format.extent | 230-235 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | acrylic resin | en |
dc.subject | glass transition temperature | en |
dc.subject | differential scanning calorimetry | en |
dc.subject | post-polymerisation treatment | en |
dc.title | Glass transition temperature of hard chairside reline materials after post-polymerisation treatments | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual de Ponta Grossa (UEPG) | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | - |
dc.description.affiliation | Ponta Grossa State Univ UEPG, Dept Dent, Ponta Grossa, PR, Brazil | - |
dc.description.affiliation | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil | - |
dc.description.affiliation | São Carlos Fed Univ UFSCar, Interdisciplinary Lab Eletrochem & Ceram, Dept Chem, São Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil | - |
dc.description.sponsorshipId | FAPESP: 02/01405-0 | - |
dc.description.sponsorshipId | FAPESP: 02/06919-1 | - |
dc.identifier.doi | 10.1111/j.1741-2358.2009.00312.x | - |
dc.identifier.wos | WOS:000281209300013 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Gerodontology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.