You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16461
Full metadata record
DC FieldValueLanguage
dc.contributor.authorManzolli Basso, Michael Frederico-
dc.contributor.authorGiampaolo, Eunice Teresinha-
dc.contributor.authorVergani, Carlos Eduardo-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorPavarina, Ana Claudia-
dc.contributor.authorRibeiro, Roberta Chuqui-
dc.date.accessioned2014-05-20T13:46:29Z-
dc.date.accessioned2016-10-25T17:00:12Z-
dc.date.available2014-05-20T13:46:29Z-
dc.date.available2016-10-25T17:00:12Z-
dc.date.issued2010-07-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1532-849X.2010.00583.x-
dc.identifier.citationJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 19, n. 5, p. 364-368, 2010.-
dc.identifier.issn1059-941X-
dc.identifier.urihttp://hdl.handle.net/11449/16461-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16461-
dc.description.abstractPurpose: The purpose of this study was to evaluate the effect of microwave disinfection (3 minutes at 650 W) on the dimensional stability of hard chairside reline resins (Kooliner, Tokuyama Rebase II, Ufi Gel hard, New Truliner) and one heat-polymerizing denture base resin (Lucitone 550).Materials and Methods: A split mold with reference points was used to make specimens (50.0-mm diameter, 0.5-mm thick) from each material, divided into five test groups (n = 8). The distances between the points on the mold were measured (gold standard), and compared with those obtained from the specimens after polymerization (baseline readings) after one, two, three, and four cycles of disinfection by microwave irradiation.Results: ANOVA and Tukey tests (alpha = 0.05) showed that Kooliner was significantly affected by all disinfection cycles (p < 0.05) when compared with baseline measurements. New Truliner resin was significantly affected by three and four cycles of microwave disinfection when compared with baseline measurements (p < 0.05). For Tokuyama Rebase II, Ufi Gel hard, and Lucitone 550, no significant dimensional changes were found.Conclusions: Microwave disinfection promoted shrinkage of Kooliner and New Truliner. The dimensional stability of Tokuyama Rebase II, Ufi Gel Hard, and Lucitone 550 was not affected by microwave disinfection.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent364-368-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectAcrylic resinen
dc.subjectpolymeren
dc.subjectcomplete dentureen
dc.subjectreliningen
dc.subjectmicrowave energyen
dc.titleInfluence of Microwave Disinfection on the Dimensional Stability of Denture Reline Polymersen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ, Dept Dent Mat & Prosthodont, Araraquara Dent Sch, UNESP, BR-14801903 Araraquara, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 05/04693-4-
dc.identifier.doi10.1111/j.1532-849X.2010.00583.x-
dc.identifier.wosWOS:000290117900005-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of Prosthodontics-implant Esthetic and Reconstructive Dentistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.