You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16469
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBasilio, Mariana de Almeida-
dc.contributor.authorButignon, Luis Eduardo-
dc.contributor.authorArioli Filho, João Neudenir-
dc.date.accessioned2014-05-20T13:46:30Z-
dc.date.accessioned2016-10-25T17:00:13Z-
dc.date.available2014-05-20T13:46:30Z-
dc.date.available2016-10-25T17:00:13Z-
dc.date.issued2012-09-01-
dc.identifierhttp://www.quintpub.com/journals/omi/abstract.php?article_id=12497#.Ui9j68bks_Y-
dc.identifier.citationInternational Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 27, n. 5, p. 1061-1067, 2012.-
dc.identifier.issn0882-2786-
dc.identifier.urihttp://hdl.handle.net/11449/16469-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16469-
dc.description.abstractPurpose: Different surface treatments have been developed in attempts to prevent the loosening of abutment screws. The aim of the current study was to compare the effectiveness of titanium alloy screws with tungsten-doped diamond-like carbon (W-DLC) coating and uncoated screws in providing stability to zirconia (ZrO2) ceramic abutments after cyclic loading. Materials and Methods: Twenty prefabricated ZrO2 ceramic abutments on their respective external-hex implants were divided into two groups of equal size according to the type of screw used: uncoated titanium alloy screw (Ti) or titanium alloy screw with W-DLC coating (W-DLC/Ti). The removal torque value (preload) of the abutment screw was measured before and after loading. Cyclic loading between 11 and 211 N was applied at an angle of 30 degrees to the long axis of the implants at a frequency of 15 Hz. A target of 0.5 x 10(6) cycles was defined. Group means were calculated and compared using analysis of variance and the F test (alpha=.05). Results: Before cyclic loading, the preload for Ti screws was significantly higher than that for W-DLC/Ti screws (P=.021). After cyclic loading, there was no significant difference between them (P=.499). Conclusions: Under the studied conditions, it can be concluded that, after cyclic loading, both abutment screws presented a significant reduction in the mean retained preload and similar effectiveness in maintaining preload. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:1061-1067en
dc.format.extent1061-1067-
dc.language.isoeng-
dc.publisherQuintessence Publishing Co Inc-
dc.sourceWeb of Science-
dc.subjectabutment screwsen
dc.subjectcyclic loadingen
dc.subjectimplant preloaden
dc.subjectscrew coating surfaceen
dc.subjectzirconia abutmenten
dc.titleEffectiveness of Screw Surface Coating on the Stability of Zirconia Abutments After Cyclic Loadingen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000310395900009-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofInternational Journal of Oral & Maxillofacial Implants-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.