You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16470
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLeao Lombardo, Carlos Eduardo-
dc.contributor.authorCanevarolo, Sebastiao Vicente-
dc.contributor.authordos Santos Nunes Reis, Jose Mauricio-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorPavarina, Ana Claudia-
dc.contributor.authorGiampaolo, Eunice Teresinha-
dc.contributor.authorVergani, Carlos Eduardo-
dc.date.accessioned2014-05-20T13:46:31Z-
dc.date.accessioned2016-10-25T17:00:13Z-
dc.date.available2014-05-20T13:46:31Z-
dc.date.available2016-10-25T17:00:13Z-
dc.date.issued2012-01-01-
dc.identifierhttp://dx.doi.org/10.1016/j.jmbbm.2011.09.011-
dc.identifier.citationJournal of The Mechanical Behavior of Biomedical Materials. Amsterdam: Elsevier B.V., v. 5, n. 1, p. 53-61, 2012.-
dc.identifier.issn1751-6161-
dc.identifier.urihttp://hdl.handle.net/11449/16470-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16470-
dc.description.abstractThis study evaluated the effect of microwave irradiation and water storage on the viscoelastic properties of two denture base resins (Lucitone 550-L and Vipi Wave-VW) and two reline resins (Kooliner-K and Tokuyama Rebase Fast II-TR II). Eight specimens (40 x 10 x 3.3 mm) of each material were evaluated by dynamic mechanical thermal analysis (DMTA) after processing, water storage for 7 days (WS), one (MW1) and 7 cycles of microwave irradiation (MW7). For each specimen, DMTA runs were carried out within different temperature intervals. Values of storage modulus (E') and loss tangent (tan 3) at 37 degrees C were obtained from the first and last runs. From the last run, values of E' at the glass transition temperature (Tg) and maximum tan delta were also recorded. Data were analyzed by a 2-way ANOVA followed by Student-Newman-Keuls test (alpha = 0.05). Measurements of the inside temperature of each specimen during microwave irradiation (650 W/3 min) were conducted using a fiber optic temperature sensor. Six specimens of each material were evaluated. During microwave irradiation, all specimens reached the boiling temperature of water at approximately 130 s. From the first DMTA run, MW1 and WS significantly increased the E' and decreased the tan delta of K at 37 degrees C (P < 0.05). From the last run, the tan 6 of K and TR II was significantly decreased after MW 1 (P < 0.05). MW 7 decreased the tan delta of K (P < 0.05). The E' of L and VW was similar and higher than K and TR II (P < 0.05). At Tg, K produced the lowest E' and its maximum tan,S was increased after MW1 (P < 0.05). The Tg mean values were arranged as: L > VW > TR II > K (P < 0.05). Microwave irradiation and WS did not detrimentally affect the viscoelastic properties of the denture base and reline resins evaluated. (C) 2011 Elsevier Ltd. All rights reserved.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent53-61-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.sourceWeb of Science-
dc.subjectAcrylic resinen
dc.subjectMicrowave irradiationen
dc.subjectGlass transitionen
dc.subjectDMTAen
dc.subjectViscoelasticen
dc.titleEffect of microwave irradiation and water storage on the viscoelastic properties of denture base and reline acrylic resinsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.description.affiliationUniv Estadual Paulista, Fac Odontol Araraquara, UNESP, Araraquara Dent Sch,Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar), Dept Mat Engn, São Paulo, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Fac Odontol Araraquara, UNESP, Araraquara Dent Sch,Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 06/00123-1-
dc.description.sponsorshipIdFAPESP: 07/01819-2-
dc.identifier.doi10.1016/j.jmbbm.2011.09.011-
dc.identifier.wosWOS:000298899200006-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofJournal of the Mechanical Behavior of Biomedical Materials-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.