You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16492
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBasso, Michael F. M.-
dc.contributor.authorGiampaolo, Eunice T.-
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorPavarina, Ana Claudia-
dc.contributor.authorVergani, Carlos Eduardo-
dc.date.accessioned2014-05-20T13:46:34Z-
dc.date.accessioned2016-10-25T17:00:15Z-
dc.date.available2014-05-20T13:46:34Z-
dc.date.available2016-10-25T17:00:15Z-
dc.date.issued2012-06-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2011.00567.x-
dc.identifier.citationGerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E815-E821, 2012.-
dc.identifier.issn0734-0664-
dc.identifier.urihttp://hdl.handle.net/11449/16492-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16492-
dc.description.abstractObjectives: An increase in occlusal vertical dimension (OVD) after microwave disinfection may result in the need for adjustments in the complete dentures. This in vitro study evaluated the increase in OVD of maxillary complete dentures submitted to microwave disinfection protocols.Material and methods: Thirty sets of complete dentures were evaluated as follows: Group 1-15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 min), once a week, for 4 weeks. Group 2-15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/ 3 min), three times a week, for 4 weeks. The vertical dimension was measured with a micrometre (in mm) before disinfection protocols (baseline readings) and after each week of disinfection. Data were analysed using Wilcoxon and Friedman tests (a = 0.05).Results: For Group 1, no significant difference was found between the increases in OVD and zero, and no significant difference was found between the weeks. For Group 2, the increases in OVD were significantly greater than zero, and the Friedman test showed that weeks 3 and 4 had significantly greater changes than week 1 and that week 4 had significantly greater change than week 2.Conclusion: Microwave disinfection only promoted significant increase in OVD in Group 2, in which the values increased progressively.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extentE815-E821-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectcomplete dentureen
dc.subjectvertical dimensionen
dc.subjectmicrowavesen
dc.subjectdisinfectionen
dc.subjectacrylic resinen
dc.titleEvaluation of the occlusion vertical dimension of complete dentures after microwave disinfectionen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, BR-14801903 Araraquara, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 05/04693-4-
dc.identifier.doi10.1111/j.1741-2358.2011.00567.x-
dc.identifier.wosWOS:000308547000115-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofGerodontology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.