You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16506
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMachado, Ana Lucia-
dc.contributor.authorGiampaolo, Eunice Teresinha-
dc.contributor.authorPavarina, Ana Claudia-
dc.contributor.authorJorge, Janaina Habib-
dc.contributor.authorVergani, Carlos Eduardo-
dc.date.accessioned2014-05-20T13:46:36Z-
dc.date.accessioned2016-10-25T17:00:17Z-
dc.date.available2014-05-20T13:46:36Z-
dc.date.available2016-10-25T17:00:17Z-
dc.date.issued2012-06-01-
dc.identifierhttp://dx.doi.org/10.1111/j.1741-2358.2011.00484.x-
dc.identifier.citationGerodontology. Hoboken: Wiley-blackwell, v. 29, n. 2, p. E375-E382, 2012.-
dc.identifier.issn0734-0664-
dc.identifier.urihttp://hdl.handle.net/11449/16506-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/16506-
dc.description.abstractBackground: This study evaluated the effect of disinfection by immersion and microwave irradiation on the roughness of one denture base resin (Lucitone-L) and five relining materials, three hard (Tokuyama Rebase II-TR, New Truliner-NT, Ufigel Hard-UH) and two resilient (Trusoft-T, Sofreliner-S).Methods: Fifty specimens were made and divided into groups: CL2 specimens were brushed with 4% chlorhexidine (1 min), immersed in the same solution (10 min) and immersed in water (3 min); MW2 specimens were immersed in water and microwave irradiated (650W; 6 min); CL2 and MW2 specimens were disinfected twice; CL7 and MW7 specimens were submitted to seven cycles using chlorhexidine or microwave irradiation, respectively; W specimens were not disinfected and remained in water (37 degrees C; 7 days).Results: Results were statistically analysed (p = 0.05) and revealed that, at baseline, the highest mean value was observed for T (p < 0.001). Material NT showed increase in roughness after the first (p = 0.003), second (p = 0.001), seventh (p = 0.000) cycles of microwave disinfection and after 7 days of immersion in water (p = 0.033).Conclusions: Resilient liner S presented significant increase in roughness after the second cycle of disinfection with chlorhexidine (p = 0.003). Material T exhibited significantly decreased roughness in group W (p = 0.010), while microwaving produced severe alterations on its surface.en
dc.format.extentE375-E382-
dc.language.isoeng-
dc.publisherWiley-Blackwell-
dc.sourceWeb of Science-
dc.subjectchemical compoundsen
dc.subjectdenture basesen
dc.subjectdenture rebasingen
dc.subjectmicrowavesen
dc.subjectsurface propertiesen
dc.titleSurface roughness of denture base and reline materials after disinfection by immersion in chlorhexidine or microwave irradiationen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Estadual de Ponta Grossa (UEPG)-
dc.description.affiliationUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil-
dc.description.affiliationUniversidade Estadual de Ponta Grossa (UEPG), Dept Dent, Maringa, Parana, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, Araraquara, SP, Brazil-
dc.identifier.doi10.1111/j.1741-2358.2011.00484.x-
dc.identifier.wosWOS:000308547000055-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofGerodontology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.