Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16526
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Del'Acqua, Marcelo Antonialli | - |
dc.contributor.author | de Avila, Erica Dorigatti | - |
dc.contributor.author | Chagas Amaral, Angela Libia | - |
dc.contributor.author | Pereira Pinelli, Ligia Antunes | - |
dc.contributor.author | Mollo Junior, Francisco de Assis | - |
dc.date.accessioned | 2014-05-20T13:46:39Z | - |
dc.date.accessioned | 2016-10-25T17:00:19Z | - |
dc.date.available | 2014-05-20T13:46:39Z | - |
dc.date.available | 2016-10-25T17:00:19Z | - |
dc.date.issued | 2012-05-01 | - |
dc.identifier | http://www.quintpub.com/journals/omi/abstract.php?article_id=12162#.Ui9kKsbks_Y | - |
dc.identifier.citation | International Journal of Oral & Maxillofacial Implants. Hanover Park: Quintessence Publishing Co Inc, v. 27, n. 3, p. 544-550, 2012. | - |
dc.identifier.issn | 0882-2786 | - |
dc.identifier.uri | http://hdl.handle.net/11449/16526 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/16526 | - |
dc.description.abstract | Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550. | en |
dc.format.extent | 544-550 | - |
dc.language.iso | eng | - |
dc.publisher | Quintessence Publishing Co Inc | - |
dc.source | Web of Science | - |
dc.subject | closed tray | en |
dc.subject | implant impression accuracy | en |
dc.subject | open tray | en |
dc.subject | splinted squared impression coping | en |
dc.subject | stock tray | en |
dc.subject | tapered impression coping | en |
dc.title | Comparison of the Accuracy of Plastic and Metal Stock Trays for Implant Impressions | en |
dc.type | outro | - |
dc.contributor.institution | Ctr Univ Araraquara | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Ctr Univ Araraquara, São Paulo, Brazil | - |
dc.description.affiliation | São Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | - |
dc.description.affiliationUnesp | São Paulo State Univ, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | - |
dc.identifier.wos | WOS:000305203300007 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Journal of Oral & Maxillofacial Implants | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.