You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/16545
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFaria-Júnior, Norberto Batista de-
dc.contributor.authorMassi, Santiago-
dc.contributor.authorCroti, Hugo Ricardo-
dc.contributor.authorGutierrez, José Carlos Rivas-
dc.contributor.authorDametto, Fábio Roberto-
dc.contributor.authorVaz, Luis Geraldo-
dc.date.accessioned2014-05-20T13:46:42Z-
dc.date.available2014-05-20T13:46:42Z-
dc.date.issued2010-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S1980-65232010000200012-
dc.identifier.citationRevista Odonto Ciência. Pontifícia Universidade Católica do Rio Grande do Sul, v. 25, n. 2, p. 170-173, 2010.-
dc.identifier.issn1980-6523-
dc.identifier.urihttp://hdl.handle.net/11449/16545-
dc.description.abstractOBJETIVO: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. METODOLOGIA: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. RESULTADOS: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. CONCLUSÃO: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).pt
dc.description.abstractPURPOSE: This study evaluated the flow rate of the Acroseal, AH Plus, Endomethasone N, Sealapex, and ActiV GP according to the standards of the ISO specification 6876/2001. METHODS: A volume of 0.05 mL of the cement mixed according to the manufacturer's recommendations was placed on a glass plate. At 180±5 s after the commencement of mixing, the second glass plate was placed on top of the sealer, followed by the weight of mass approximately 100 g to make a total mass on the plate of 120±2 g. Ten min after the start of mixing, the weight was removed and the value of the diameter of the compressed disc of sealer was measured. The mean of three such determinations for each sealer was taken as the flow of the material. The mean values were compared using ANOVA and Tukey's tests. RESULTS: The results obtained were: Acroseal 21.24 mm, AH Plus 22.72 mm, ActiV GP 24.90 mm, Endomethasone N 18.76 mm, and Sealapex 25.15 mm. CONCLUSION: Only the Endomethasone N did not conform to ISO Specification that requires that a sealer shall have a diameter of not less than 20 mm. The Sealapex achieved the greatest flow, but it did not differ from Activ GP and AH Plus (P>0.5).en
dc.format.extent170-173-
dc.language.isoeng-
dc.publisherPontifícia Universidade Católica do Rio Grande do Sul (PUC-RS)-
dc.sourceSciELO-
dc.subjectEscoamentopt
dc.subjectmateriais dentáriospt
dc.subjectcimentos obturadorespt
dc.subjectFlowen
dc.subjectdental materialsen
dc.subjectroot canal sealersen
dc.titleComparative assessment of the flow rate of root canal sealersen
dc.title.alternativeEstudo comparativo do escoamento de cimentos obturadores endodônticospt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Potiguar Programa de Pós-Graduação em Odontologia-
dc.description.affiliationUNESP Faculdade de Odontologia de Araraquara Programa de Pos-Graduação em Endodontia-
dc.description.affiliationUniversidade Potiguar Programa de Pós-Graduação em Odontologia-
dc.description.affiliationUNESP Faculdade de Odontologia de Araraquara Departamento de Materiais Dentários e Prótese-
dc.description.affiliationUnespUNESP Faculdade de Odontologia de Araraquara Programa de Pos-Graduação em Endodontia-
dc.description.affiliationUnespUNESP Faculdade de Odontologia de Araraquara Departamento de Materiais Dentários e Prótese-
dc.identifier.doi10.1590/S1980-65232010000200012-
dc.identifier.scieloS1980-65232010000200012-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1980-65232010000200012.pdf-
dc.relation.ispartofRevista Odonto Ciência-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.