Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16660
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bandeca, Matheus Coelho | - |
dc.contributor.author | Pinto, Shelon Cristina Souza | - |
dc.contributor.author | Calixto, Luiz Rafael | - |
dc.contributor.author | Saad, José Roberto Cury | - |
dc.contributor.author | Barros, Érico Luiz Damasceno | - |
dc.contributor.author | Shelb, Amr | - |
dc.date.accessioned | 2014-05-20T13:46:57Z | - |
dc.date.available | 2014-05-20T13:46:57Z | - |
dc.date.issued | 2012-08-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S1516-14392012005000060 | - |
dc.identifier.citation | Materials Research. ABM, ABC, ABPol, v. 15, n. 4, p. 491-494, 2012. | - |
dc.identifier.issn | 1516-1439 | - |
dc.identifier.uri | http://hdl.handle.net/11449/16660 | - |
dc.description.abstract | The purpose of this study was to investigate the bond strength of fiber post previously laser treated root canals. Forty single-rooted bovine teeth were endodontically treated, randomly and equally divided into two main groups according to the type of pretreatment: G1: 2.5% NaOCl (control group); and G2: Er,Cr:YSGG laser. Each group was further subdivided into 2 groups based on the category of adhesive systems/ luting materials used: a: an etch-and-rinse resin cement (Single Bond/RelyX ARC; 3M ESPE), and b: a self-adhesive resin cement (Rely X Unicem; 3M ESPE). Three 1.5 mm thick slabs were obtained per root and the push-out test was performed at a crosshead speed of 0.5 mm/min until post dislodgement occurred. Data were analyzed by ANOVA and post-hoc Tukey's test at a pre-set alpha of 0.05. Analysis of variance showed no statistically significant difference (p > 0.05) among the groups G1a (25.44 ± 2.35) and G1b (23.62 ± 3.48), G2a (11.77 ± 2.67) and G2b (9.93 ± 3.37). Fractures were observed at the interface between the dentin and the resin in all groups. The Er,Cr:YSGG laser irradiation did not influence on the bond strength of the resin cements and the etch-and-rinse resin cement had better results on bond strength than self-adhesive resin cement. | en |
dc.format.extent | 491-494 | - |
dc.language.iso | eng | - |
dc.publisher | ABM, ABC, ABPol | - |
dc.source | SciELO | - |
dc.subject | Er,Cr:YSGG laser | en |
dc.subject | root canal dentin | en |
dc.subject | push-out bond strength | en |
dc.subject | fiber post | en |
dc.subject | resin cement | en |
dc.title | Influence of Er,Cr: YSGG laser on bond strength of self-adhesive resin cement | en |
dc.type | outro | - |
dc.contributor.institution | Centre Universitary of Maranhão Department of Dentistry | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Suez Canal University Faculty of Dentistry Department of Restorative Dentistry | - |
dc.description.affiliation | Centre Universitary of Maranhão Department of Dentistry | - |
dc.description.affiliation | UNESP Araraquara Dental School Department of Restorative Dentistry | - |
dc.description.affiliation | Suez Canal University Faculty of Dentistry Department of Restorative Dentistry | - |
dc.description.affiliationUnesp | UNESP Araraquara Dental School Department of Restorative Dentistry | - |
dc.identifier.doi | 10.1590/S1516-14392012005000060 | - |
dc.identifier.scielo | S1516-14392012000400001 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S1516-14392012000400001.pdf | - |
dc.relation.ispartof | Materials Research | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.