Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16685
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Calixto, L. R. | - |
dc.contributor.author | Lima, D. M. | - |
dc.contributor.author | Queiroz, R. S. | - |
dc.contributor.author | Rastelli, Alessandra Nara de Souza | - |
dc.contributor.author | Bagnato, V. S. | - |
dc.contributor.author | Andrade, M. F. | - |
dc.date.accessioned | 2014-05-20T13:47:01Z | - |
dc.date.accessioned | 2016-10-25T17:00:33Z | - |
dc.date.available | 2014-05-20T13:47:01Z | - |
dc.date.available | 2016-10-25T17:00:33Z | - |
dc.date.issued | 2008-11-01 | - |
dc.identifier | http://dx.doi.org/10.1134/S1054660X08110303 | - |
dc.identifier.citation | Laser Physics. New York: Maik Nauka/interperiodica/springer, v. 18, n. 11, p. 1365-1369, 2008. | - |
dc.identifier.issn | 1054-660X | - |
dc.identifier.uri | http://hdl.handle.net/11449/16685 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/16685 | - |
dc.description.abstract | The purpose of this study was to evaluate the polymerization effectiveness of a composite resin (Z-250) utilizing microhardness testing. In total, 80 samples with thicknesses of 2 and 4 mm were made, which were photoactivated by a conventional halogen light-curing unit, and light-curing units based on LED. The samples were stored in water distilled for 24 h at 37C. The Vickers microhardness was performed by the MMT-3 microhardness tester. The microhardness means obtained were as follows: G1, 72.88; G2, 69.35; G3, 67.66; G4, 69.71; G5, 70.95; G6, 75.19; G7, 72.96; and G8, 71.62. The data were submitted to an analysis of variance (ANOVA's test), adopting a significance level of 5%. The results showed that, in general, there were no statistical differences between the halogen and LED light-curing units used with the same parameters. | en |
dc.format.extent | 1365-1369 | - |
dc.language.iso | eng | - |
dc.publisher | Maik Nauka/interperiodica/springer | - |
dc.source | Web of Science | - |
dc.title | Curing depth of composite resin light cured by LED and halogen light-curing units | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | UNESP, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | - |
dc.description.affiliation | USP, Phys Inst São Carlos, BR-13560970 São Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1134/S1054660X08110303 | - |
dc.identifier.wos | WOS:000260854700030 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Laser Physics | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.