Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/16751
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tanomaru-Filho, M. | - |
dc.contributor.author | Pinto, R. V. S. | - |
dc.contributor.author | Bosso, R. | - |
dc.contributor.author | Nascimento, C. A. | - |
dc.contributor.author | Berbert, Fabio Luiz Camargo Villela | - |
dc.contributor.author | Guerreiro-Tanomaru, J. M. | - |
dc.date.accessioned | 2014-05-20T13:47:10Z | - |
dc.date.accessioned | 2016-10-25T17:00:40Z | - |
dc.date.available | 2014-05-20T13:47:10Z | - |
dc.date.available | 2016-10-25T17:00:40Z | - |
dc.date.issued | 2011-08-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1365-2591.2011.01889.x | - |
dc.identifier.citation | International Endodontic Journal. Malden: Wiley-blackwell, v. 44, n. 8, p. 764-768, 2011. | - |
dc.identifier.issn | 0143-2885 | - |
dc.identifier.uri | http://hdl.handle.net/11449/16751 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/16751 | - |
dc.description.abstract | Aim To analyse the thermoplasticity of several endodontic filling materials using the Obtura II System at different temperature settings.Methodology The following materials based on gutta-percha: Regular Obtura (OBT), Obtura Flow 150 (OBT F), Endo Flow (EDF), Odous (ODO) and the synthetic thermoplastic polymer material Resilon (RE) were heated using the Obtura II System at three temperature settings (140, 170 and 200 degrees C). Samples of the heated materials were placed on the sensor of a digital thermometer (THR-140; Instrutherm, São Paulo, Brazil) to determine their real temperature (RT) when the system was set at 140 degrees C (from 64.5 to 69 degrees C), 170 degrees C (from 73.8 to 77.5 degrees C) and 200 degrees C (from 83.6 degrees C for EDF and 100 degrees C for RE). Specimens (n = 30) were made by placing samples of each material in metallic ring moulds and compressing them between two glass slabs. After 24 h, specimens (n = 10) were heated at the different settings (RT) and submitted to compression under a 5-kg load. Plasticization was assessed by calculating the differences between the post-compression and initial diameters of each specimen. Data were submitted to ANOVA and Tukey's test at 5% significance.Results At 140 degrees C, Obtura Flow presented the highest thermoplasticity values and Regular Obtura, the lowest. At 170 degrees C, Obtura Flow and Resilon demonstrated greater plasticization. Resilon had the highest mean thermoplasticity values at 200 degrees C.Conclusions Thermoplasticity values were influenced both by the temperature settings on the Obtura II System and by the type of material analysed. Obtura Flow and Resilon had the highest mean thermoplasticity values. | en |
dc.format.extent | 764-768 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | gutta-percha | en |
dc.subject | root canal filling materials | en |
dc.subject | root canal obturation | en |
dc.title | Evaluation of the thermoplasticity of gutta-percha and Resilon (R) using the Obtura II System at different temperature settings | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | UNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, Brazil | - |
dc.description.affiliationUnesp | UNESP, Araraquara Dent Sch, Dept Restorat Dent, Araraquara, Brazil | - |
dc.identifier.doi | 10.1111/j.1365-2591.2011.01889.x | - |
dc.identifier.wos | WOS:000292336400007 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | International Endodontic Journal | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.