Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/1732
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gava, F.N. | - |
dc.contributor.author | Paulino-Junior, D. | - |
dc.contributor.author | Pereira-Neto, G.B. | - |
dc.contributor.author | Pascon, J.P.E. | - |
dc.contributor.author | Sousa, M.G. | - |
dc.contributor.author | Chanpion, T. | - |
dc.contributor.author | Camacho, Aparecido Antonio | - |
dc.date.accessioned | 2014-05-20T13:14:12Z | - |
dc.date.available | 2014-05-20T13:14:12Z | - |
dc.date.issued | 2011-04-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S0102-09352011000200007 | - |
dc.identifier.citation | Arquivo Brasileiro de Medicina Veterinária e Zootecnia. Universidade Federal de Minas Gerais, Escola de Veterinária, v. 63, n. 2, p. 317-321, 2011. | - |
dc.identifier.issn | 0102-0935 | - |
dc.identifier.uri | http://hdl.handle.net/11449/1732 | - |
dc.description.abstract | Estudaram-se os parâmetros eletrocardiográficos utilizando-se os métodos convencional, computadorizado e computadorizado impresso de 30 cães da raça Beagle clinicamente normais. As medidas eletrocardiográficas dos três diferentes traçados foram analisadas na derivação DII. A comparação entre os métodos revelou diferença nos valores da onda P, onda R, complexo QRS, intervalo QT e intervalo PR e na polaridade da onda T. Este fato deve ser levado em consideração, na dependência do método a ser utilizado. | pt |
dc.description.abstract | Electrocardiographic parameters were studied in thirty healthy adult Beagles, using conventional and computerized methods and reading the computerized registration printed on paper. The electrocardiographic measurements of the three different tracings were analyzed in lead II. The results obtained showed that there are differences among the three methods for P wave, R wave, QRS complex, QT interval, PR interval and polarity of the T wave. Special attention should be given to these differences, depending on the chosen method. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.format.extent | 317-321 | - |
dc.language.iso | por | - |
dc.publisher | Universidade Federal de Minas Gerais (UFMG), Escola de Veterinária | - |
dc.source | SciELO | - |
dc.subject | Dog | en |
dc.subject | electrocardiogram | en |
dc.subject | Cão | pt |
dc.subject | eletrocardiograma | pt |
dc.title | Eletrocardiografia computadorizada em cães da raça Beagle | pt |
dc.title.alternative | Computerised electrocardiograph in Beagle dogs | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Unesp Faculdade de Ciências Agrárias e Veterinárias | - |
dc.description.affiliationUnesp | Unesp Faculdade de Ciências Agrárias e Veterinárias | - |
dc.identifier.doi | 10.1590/S0102-09352011000200007 | - |
dc.identifier.scielo | S0102-09352011000200007 | - |
dc.identifier.wos | WOS:000291825100007 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S0102-09352011000200007.pdf | - |
dc.relation.ispartof | Arquivo Brasileiro de Medicina Veterinária e Zootecnia | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.