Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/1785
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rached, Paula A. | - |
dc.contributor.author | Canola, Julio C. | - |
dc.contributor.author | Schlueter, Claudia | - |
dc.contributor.author | Laus, Jose L. | - |
dc.contributor.author | Oechtering, Gerhard | - |
dc.contributor.author | de Almeida, Denise E. | - |
dc.contributor.author | Ludewig, Eberhard | - |
dc.date.accessioned | 2014-05-20T13:14:16Z | - |
dc.date.accessioned | 2016-10-25T16:35:18Z | - |
dc.date.available | 2014-05-20T13:14:16Z | - |
dc.date.available | 2016-10-25T16:35:18Z | - |
dc.date.issued | 2011-05-01 | - |
dc.identifier | http://dx.doi.org/10.1111/j.1463-5224.2010.00861.x | - |
dc.identifier.citation | Veterinary Ophthalmology. Malden: Wiley-blackwell, v. 14, n. 3, p. 174-179, 2011. | - |
dc.identifier.issn | 1463-5216 | - |
dc.identifier.uri | http://hdl.handle.net/11449/1785 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/1785 | - |
dc.description.abstract | The aims of the study were (1) to quantify the influence of selected imaging parameters on the image quality (slice thickness, mAs, and beam orientation) defining optimal conditions for scan protocols and (2) to evaluate the benefits of the 3D reconstruction techniques for visualization of NDS structures in dogs. CT-DCG was performed bilaterally in 32 heads of dogs. CT transverse images were obtained using a combination of two slice thickness values (0.8 mm and 2 mm) and two mAs values (50 mAs and 300 mAs). Two beam projection orientations were also tested: transverse plane (perpendicular to the hard palate) and oblique to the hard palate. Three-dimensional images were obtained using Volume Rendering (VR). Transverse beam projection proved to be superior for the assessment of the inferior and superior lacrimal canaliculi and lacrimal sac. In this study, there was no statistical difference regarding mAs values (50 mAs and 300 mAs) and slice thickness values (0.8 mm and 2 mm). Three-dimensional images were helpful for the assessment of topographic relationship between nasolacrimal structures and cranial landmarks. | en |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.description.sponsorship | Deutscher Akademischer Austauschdienst (DAAD) | - |
dc.format.extent | 174-179 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | Canine | en |
dc.subject | Computed tomography | en |
dc.subject | CT-DCG | en |
dc.subject | Dacryocystography | en |
dc.subject | Dog | en |
dc.subject | Nasolacrimal system | en |
dc.title | Computed tomographic-dacryocystography (CT-DCG) of the normal canine nasolacrimal drainage system with three-dimensional reconstruction | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Univ Leipzig | - |
dc.description.affiliation | São Paulo State Univ, Dept Vet Clin & Surg, Coll Agr & Veterinarian Sci, Jaboticabal, SP, Brazil | - |
dc.description.affiliation | Univ Leipzig, Dept Small Anim Med, Fac Vet Med, D-04103 Leipzig, Germany | - |
dc.description.affiliationUnesp | São Paulo State Univ, Dept Vet Clin & Surg, Coll Agr & Veterinarian Sci, Jaboticabal, SP, Brazil | - |
dc.identifier.doi | 10.1111/j.1463-5224.2010.00861.x | - |
dc.identifier.wos | WOS:000289950500005 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Veterinary Ophthalmology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.