Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/18997
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | da Silva, S. M. | - |
dc.contributor.author | Mazo, L. H. | - |
dc.date.accessioned | 2014-05-20T13:53:16Z | - |
dc.date.accessioned | 2016-10-25T17:03:54Z | - |
dc.date.available | 2014-05-20T13:53:16Z | - |
dc.date.available | 2016-10-25T17:03:54Z | - |
dc.date.issued | 1998-12-01 | - |
dc.identifier | http://dx.doi.org/10.1002/(SICI)1521-4109(199811)10:17<1200 | - |
dc.identifier.citation | Electroanalysis. Berlin: Wiley-v C H Verlag Gmbh, v. 10, n. 17, p. 1200-1203, 1998. | - |
dc.identifier.issn | 1040-0397 | - |
dc.identifier.uri | http://hdl.handle.net/11449/18997 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/18997 | - |
dc.description.abstract | The application of disk shaped gold ultramicroelectrode for nitrite determination with and without addition of supporting electrolyte was studied using the differential pulse voltammetric method. The well-defined peak for nitrite oxidation near 0.8V (vs. Ag/AgCl reference electrode) was used to obtain analytical plots in the concentration range from 0.1 to 0.6 mmol L-1 and from 10.0 to 50.0 mu mol.L-1. The calculated detection limit was 0.65 mu mol.L-1 in purified water, in the absence of supporting electrolyte, with relative standard deviation of 1.36% (n=6) for analyzing 10.0 mu mol L-1 nitrite solutions, and accuracy of 100.9 %, based on recovery studies. The application of this analytical method to mineral and river water samples of natural pH also showed improved sensitivity when compared with the linear sweep voltammetric method previously reported. | en |
dc.format.extent | 1200-1203 | - |
dc.language.iso | eng | - |
dc.publisher | Wiley-Blackwell | - |
dc.source | Web of Science | - |
dc.subject | nitrite | pt |
dc.subject | ultramicroelectrodes | pt |
dc.subject | natural water | pt |
dc.subject | differential pulse voltammetry | pt |
dc.title | Differential pulse voltammetric determination of nitrite with gold ultramicroelectrode | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | UNESP, Inst Biociencias, Dept Quim, BR-18618000 Botucatu, SP, Brazil | - |
dc.description.affiliation | Univ São Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil | - |
dc.description.affiliationUnesp | UNESP, Inst Biociencias, Dept Quim, BR-18618000 Botucatu, SP, Brazil | - |
dc.identifier.doi | 10.1002/(SICI)1521-4109(199811)10:17<1200 | - |
dc.identifier.wos | WOS:000078205000009 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Electroanalysis | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.