You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/19045
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRoldan, P. S.-
dc.contributor.authorAlcantara, I. L.-
dc.contributor.authorCastro, G. R.-
dc.contributor.authorRocha, Julio Cesar-
dc.contributor.authorPadilha, CCF-
dc.contributor.authorPadilha, P. M.-
dc.date.accessioned2014-05-20T13:53:22Z-
dc.date.accessioned2016-10-25T17:03:57Z-
dc.date.available2014-05-20T13:53:22Z-
dc.date.available2016-10-25T17:03:57Z-
dc.date.issued2003-02-01-
dc.identifierhttp://dx.doi.org/10.1007/s00216-002-1735-7-
dc.identifier.citationAnalytical and Bioanalytical Chemistry. Berlin: Springer-verlag Berlin, v. 375, n. 4, p. 574-577, 2003.-
dc.identifier.issn1618-2642-
dc.identifier.urihttp://hdl.handle.net/11449/19045-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/19045-
dc.description.abstractThis work describes the synthesis and characterization of 2-aminothiazole-modified silica gel (SiAT), as well as its application for preconcentration (in batch and column technique) of Cu(II), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities of SiAT determined for each metal ion were (mmol g(-1)): Cu(II)=1.20, Ni(II)=1.10 and Zn(II)=0.90. In addition, results obtained in flow experiments, showed a recovery of ca. 100% of the metal ions adsorbed in a column packed with 500 mg of SiAT. The eluent was 2.0 mol L-1 HCl. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in fuel ethanol using flame AAS for their quantification.en
dc.format.extent574-577-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.subjectpreconcentrationpt
dc.subject2-aminothiazole-modified silica gelpt
dc.subjectfuel ethanolpt
dc.titleDetermination of Cu, Ni, and Zn in fuel ethanol by FAAS after enrichment in column packed with 2-aminothiazole-modified silica gelen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Inst Biociencias, Dept Quim & Bioquim, BR-18618000 Botucatu, SP, Brazil-
dc.description.affiliationUNESP, Dept Quim Analit, Inst Quim, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista Julio Mesquita Filho, Inst Biociencias, Dept Fis & Biophys, BR-18618000 Botucatu, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Inst Biociencias, Dept Quim & Bioquim, BR-18618000 Botucatu, SP, Brazil-
dc.description.affiliationUnespUNESP, Dept Quim Analit, Inst Quim, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista Julio Mesquita Filho, Inst Biociencias, Dept Fis & Biophys, BR-18618000 Botucatu, SP, Brazil-
dc.identifier.doi10.1007/s00216-002-1735-7-
dc.identifier.wosWOS:000181659600018-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytical and Bioanalytical Chemistry-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.