You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/20647
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCaputo, Fabrizio-
dc.contributor.authorGreco, Camila Coelho-
dc.contributor.authorDenadai, Benedito Sérgio-
dc.date.accessioned2013-09-30T19:26:02Z-
dc.date.accessioned2014-05-20T13:57:59Z-
dc.date.available2013-09-30T19:26:02Z-
dc.date.available2014-05-20T13:57:59Z-
dc.date.issued2005-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0066-782X2005000100005-
dc.identifier.citationArquivos Brasileiros de Cardiologia. Sociedade Brasileira de Cardiologia - SBC, v. 84, n. 1, p. 20-23, 2005.-
dc.identifier.issn0066-782X-
dc.identifier.urihttp://hdl.handle.net/11449/20647-
dc.description.abstractOBJETIVO: Determinar os efeitos do estado e especificidade de treinamento aeróbio na relação entre o percentual do consumo máximo de oxigênio (%VO2max) e o percentual da frequência cardíaca máxima (%FCmax) durante o exercício incremental realizado no cicloergômetro. MÉTODOS: Sete corredores, 9 ciclistas, 11 triatletas e 12 sedentários, todos do sexo masculino e aparentemente saudáveis, foram submetidos a um teste incremental até a exaustão no cicloergômetro. Regressões lineares entre %VO2max e %FCmax foram determinadas para cada indivíduo. Com base nessas regressões, foram calculados %FCmax correspondentes a determinados %VO2max (50, 60, 70, 80 e 90%) de cada participante. RESULTADOS: Não foram encontradas diferenças significantes entre todos os grupos nos %FCmax para cada um dos %VO2max avaliados. Analisando-se os voluntários como um único grupo, as médias dos %FCmax correspondentes a 50, 60, 70, 80 e 90% %VO2max foram 67, 73, 80, 87, e 93%, respectivamente. CONCLUSÃO: Nos grupos analisados, a relação entre o %VO2max e %FCmax durante o exercício incremental no ciclismo não é dependente do estado e especificidade do treinamento aeróbio.pt
dc.description.abstractOBJECTIVE: To determine the effects of the status and specificity of exercise training in the ratio between maximum oxygen consumption (%VO2max) and the percentage of maximal heart rate (%HRmax) during incremental exercise on a cycle ergometer. METHODS: Seven runners, 9 cyclists, 11 triathletes, and 12 sedentary individuals, all male and apparently healthy, underwent exhaustive incremental exercise on cycle ergometers. Linear regressions between %VO2max x %HRmax were determined for each individual. Based on these regressions, %HRmax was assessed corresponding to a determined %VO2max (50, 60, 70, 80, and 90%) from each participant. RESULTS: Significant differences were not found between the groups in %HRmax for each of the %VO2max assessed. Analyzing the volunteers as a single group, the average of the corresponding %HRmax to 50, 60, 70, 80, and 90% %VO2max were 67, 73, 80, 87, and 93%, respectively. CONCLUSION: The ratio between %VO2max and %HRmax in the groups assessed during incremental exercise on the bicycle is not dependent on the status and specificity of aerobic exercise training.en
dc.format.extent20-23-
dc.language.isopor-
dc.publisherSociedade Brasileira de Cardiologia (SBC)-
dc.sourceSciELO-
dc.subjectConsumo de oxigêniopt
dc.subjectfreqüência cardíacapt
dc.subjectprescrição do exercíciopt
dc.subjectestado de treinamentopt
dc.subjectciclismopt
dc.subjectoxygen consumptionen
dc.subjectheart rateen
dc.subjectexercise prescriptionen
dc.subjecttraining statusen
dc.subjectcyclingen
dc.titleEfeitos do estado e especificidade do treinamento aeróbio na relação %VO2max versus %FCmax durante o ciclismopt
dc.title.alternativeEffects of the state and specificity of aerobic training on the %VO2max versus %HRmax ratio during cyclingen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Laboratório de Avaliação da Performance Humana-
dc.description.affiliationUnespUNESP Laboratório de Avaliação da Performance Humana-
dc.identifier.doi10.1590/S0066-782X2005000100005-
dc.identifier.scieloS0066-782X2005000100005-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0066-782X2005000100005.pdf-
dc.relation.ispartofArquivos Brasileiros de Cardiologia-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.