Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/20661
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jambassi Filho, José Claudio | - |
dc.contributor.author | Cyrino, Edilson Serpeloni | - |
dc.contributor.author | Gurjão, André Luiz Demantova | - |
dc.contributor.author | Braz, Igor Augusto | - |
dc.contributor.author | Gonçalves, Raquel | - |
dc.contributor.author | Gobbi, Sebastião | - |
dc.date.accessioned | 2013-09-30T19:28:31Z | - |
dc.date.accessioned | 2014-05-20T13:58:03Z | - |
dc.date.available | 2013-09-30T19:28:31Z | - |
dc.date.available | 2014-05-20T13:58:03Z | - |
dc.date.issued | 2010-02-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S1517-86922010000100002 | - |
dc.identifier.citation | Revista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 16, n. 1, p. 13-17, 2010. | - |
dc.identifier.issn | 1517-8692 | - |
dc.identifier.uri | http://hdl.handle.net/11449/20661 | - |
dc.description.abstract | O objetivo deste estudo foi analisar as estimativas da composição corporal e a concordância das medidas produzidas por meio de dois diferentes analisadores de impedância bioelétrica em homens adultos jovens. Vinte e dois sujeitos (23,6 ± 2,9 anos; 73 ± 6,8kg; 177,6 ± 6,0cm; 23,1 ± 1,9kg/m²), aparentemente saudáveis, foram submetidos a medidas de impedância bioelétrica por meio dos analisadores tetrapolar de corpo inteiro (TCI, Biodynamic Body Composition Analyser, modelo 310) e bipolar para membros superiores (BMS, Omron tm, modelo HBF-306BL) após jejum de 12h. Estimativas da gordura corporal relativa (%GC), massa livre de gordura (MLG) e massa gorda (MG) foram estabelecidas a partir das informações fornecidas pelos dois equipamentos. Nenhuma diferença estatisticamente significante foi verificada para %GC (10,9 ± 4,3 vs. 10,0 ± 4,2%; P = 0,09), MG (8,1 ± 3,5 vs. 7,4 ± 3,5kg; P = 0,10) e MLG (64,9 ± 5,2 vs. 65,5 ± 4,9kg; P = 0,09) entre TCI e BMS, respectivamente. Correlações positivas e significantes (P < 0,001) foram encontradas entre os analisadores para MLG (r = 0,948), MG (r = 0,891) e %GC (r = 0,859). Os limites de concordância foram de -0,6 ± 3,2kg para a MLG (r = 0,135; P = 0,551), 0,8 ± 4,5% para a %GC (r = 0,050; P = 0,824) e 0,6 ± 3,2kg para a MG (r = 0,032; P = 0,886). Os resultados sugerem que as estimativas da composição corporal por impedância bioelétrica não parecem ser afetadas pelo uso de diferentes analisadores (BMS vs. TCI) ou pela adiposidade corporal total. | pt |
dc.description.abstract | The aim of this study was to analyze the body composition estimation and agreement of the measurements produced from two bioelectrical impedance analysers in young adult men. Twenty-two apparently healthy subjects (23.6 ± 2.9 yrs; 73.0 ± 6.8 kg; 177.6 ± 6.0 cm; 23.1 ± 1.9 kg/m²), were submitted to bioelectrical impedance measurements by tetra-polar whole body (TWB, Biodynamic Body Composition Analyser, model 310) and bipolar for upper body (BUB, OMRON TM, model HBF-306BL) after 12 h fast. Relative body fat (%BF), lean body mass (LBM) and fat mass (FM) estimation were established from information supplied by two analysers. No significant difference was verified for %BF (10.9 ±4.3 vs. 10.0 ±4.2%; P = 0.09), FM (8.1 ±3.5 vs. 7.4 ±3.5 kg; P = 0.10) or LBM (64.9 ±5.2 vs. 65.5 ±4.9 kg; P = 0.09) between TWB and BUB, respectively. Positive significant correlations (P < 0.001) were found between both analysers for LBM (r = 0.948), FM (r = 0.891) and %BF (r = 0.859). The agreement thresholds were -0.6 ± 3.2 kg for LBM (r = 0.135; P = 0.551), 0.8 ± 4.5% for %BF (r = 0.050; P = 0.824), and 0.6 ± 3.2 kg for FM (r = 0.032; P = 0.886). The results suggest that the body composition estimation by bioelectrical impedance does not seem to be affected by use of different analysers (BUB vs. TWB) or the total body adiposity. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | - |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.format.extent | 13-17 | - |
dc.language.iso | por | - |
dc.publisher | Sociedade Brasileira de Medicina do Exercício e do Esporte | - |
dc.source | SciELO | - |
dc.subject | massa livre de gordura | pt |
dc.subject | gordura corporal | pt |
dc.subject | impedância bioelétrica | pt |
dc.subject | lean body mass | en |
dc.subject | body fat | en |
dc.subject | bioelectrical impedance | en |
dc.title | Estimativa da composição corporal e análise de concordância entre analisadores de impedância bioelétrica bipolar e tetrapolar | pt |
dc.title.alternative | Body composition estimation and agreement analysis between bipolar and tetrapolar bioelectrical impedance analyzers | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Universidade Estadual de Londrina (UEL) | - |
dc.description.affiliation | Universidade Estadual Paulista IB DEF | - |
dc.description.affiliation | Universidade Estadual de Londrina (UEL) Centro de Educação Física e Esporte Grupo de Estudo e Pesquisa em Metabolismo, Nutrição e Exercício | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista IB DEF | - |
dc.identifier.doi | 10.1590/S1517-86922010000100002 | - |
dc.identifier.scielo | S1517-86922010000100002 | - |
dc.identifier.wos | WOS:000276904700002 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S1517-86922010000100002.pdf | - |
dc.relation.ispartof | Revista Brasileira de Medicina do Esporte | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.