You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/20688
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCalis, João Francisco Francelin-
dc.contributor.authorDenadai, Benedito Sérgio-
dc.date.accessioned2013-09-30T19:28:12Z-
dc.date.accessioned2014-05-20T13:58:11Z-
dc.date.available2013-09-30T19:28:12Z-
dc.date.available2014-05-20T13:58:11Z-
dc.date.issued2000-02-01-
dc.identifierhttp://dx.doi.org/10.1590/S1517-86922000000100002-
dc.identifier.citationRevista Brasileira de Medicina do Esporte. Sociedade Brasileira de Medicina do Exercício e do Esporte, v. 6, n. 1, p. 1-4, 2000.-
dc.identifier.issn1517-8692-
dc.identifier.urihttp://hdl.handle.net/11449/20688-
dc.description.abstractO objetivo deste estudo foi verificar o efeito da seleção das cargas e do modelo utilizado para a determinação da PC no ergômetro de braço. Participaram do estudo oito voluntários do sexo masculino, que praticavam atividade física regularmente e eram aparentemente saudáveis. Os sujeitos realizaram quatro testes com cargas constantes mantidas até a exaustão voluntária no ergômetro de braço UBE 2462-Cybex. As cargas foram individualmente selecionadas para induzir a fadiga entre 1 e 15 minutos. Para cada sujeito, a determinação da PC foi realizada através de dois modelos lineares: potência-1/tempo e trabalho-tempo. em cada um dos modelos, foram utilizadas todas as potências (1), as três maiores (2) e as três menores (3). As PC encontradas no modelo potência-1/tempo e trabalho-tempo para a condição 3 (177,5 + 29,5; 173,9 + 33,3, respectivamente) foram significantemente menores do que as da condição 2 (190,5 + 23,2; 183,4 + 22,3, respectivamente), não existindo diferenças destas com as da condição 1 (184,2 + 25,4; 176,4 + 28,8, respectivamente). As PC determinadas no modelo potência-1/tempo para as condições 1 e 2 foram significantemente maiores do que as determinadas no modelo trabalho-tempo, não existindo diferenças para a condição 3. Pode-se concluir que as cargas selecionadas e o modelo utilizado interferem na determinação da PC encontrada no ergômetro de braço, podendo interferir no tempo de exaustão durante o exercício submáximo realizado em cargas relativas a este índice.pt
dc.description.abstractThe aim of this study was to verify the effect of selected loads and the model used to determine CP in the arm ergometer. Eight active males apparently healthy participated in the study. The subjects performed 4 tests with constant loads maintained until the voluntary exhaustion in the arm ergometer (UBE 2462-Cybex). The loads were individually selected to induce fatigue between 1 and 15 minutes. For each subject, the determination of CP was accomplished by two linear models: power-1/time and work-time. In each model, the CP was calculated using: all power outputs (1), the three highest (2), and the three lowest outputs (3). The CP in the power-1/time and work-time models for the condition 3 (177.5 + 29.5; 173.9 + 33.3, respectively) were lower than for the condition 2 (190.5 + 23.2; 183.4 + 22.3, respectively), no difference existing between condition 2 and 1 (184.2 + 25.4; 176.4 + 28.8, respectively). The CP determined in the power-1/time model for conditions 1 and 2 were higher than in the work-time model, no difference existing for condition 3. It can be concluded that the selected loads and the model used interfere in the determination of CP during arm crank exercise, and can modify the time to exhaustion during submaximal exercise performed in relative loads to CP.en
dc.format.extent1-4-
dc.language.isopor-
dc.publisherSociedade Brasileira de Medicina do Exercício e do Esporte-
dc.sourceSciELO-
dc.subjectPotência críticapt
dc.subjectModelo linearpt
dc.subjectTempo de exaustãopt
dc.subjectErgômetro de braçopt
dc.subjectCritical poweren
dc.subjectLinear modelen
dc.subjectTime to exhaustionen
dc.subjectArm ergometeren
dc.titleInfluência das cargas selecionadas na determinação da potência crítica determinada no ergômetro de braço em dois modelos linearespt
dc.title.alternativeEffect of selected loads on the critical power determination in the arm ergometer by two linear modelsen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUnesp Departamento de Educação Física Laboratório de Avaliação da Performance Humana-
dc.description.affiliationUnespUnesp Departamento de Educação Física Laboratório de Avaliação da Performance Humana-
dc.identifier.doi10.1590/S1517-86922000000100002-
dc.identifier.scieloS1517-86922000000100002-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1517-86922000000100002.pdf-
dc.relation.ispartofRevista Brasileira de Medicina do Esporte-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.