dc.contributor.authorMomesso, J.C.-
dc.contributor.authorMachado Neto, J.G.-
dc.date.accessioned2014-05-20T13:15:08Z-
dc.date.available2014-05-20T13:15:08Z-
dc.date.issued2003-12-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-83582003000300016-
dc.identifier.citationPlanta Daninha. Sociedade Brasileira da Ciência das Plantas Daninhas , v. 21, n. 3, p. 467-478, 2003.-
dc.identifier.issn0100-8358-
dc.identifier.urihttp://hdl.handle.net/11449/2364-
dc.description.abstractO objetivo deste trabalho foi avaliar os efeitos do período e volume de aplicação na segurança da atividade de tratoristas aplicando herbicidas na cultura de cana-de-açúcar com o pulverizador de barra montado em trator e a eficiência de equipamentos de proteção individual (EPIs) e de uma cabina acoplada ao trator. As exposições dérmicas de 13 condições de trabalho foram avaliadas e analisadas estatisticamente por meio do delineamento inteiramente ao acaso e do esquema fatorial 3 x 2 x 2 + 1. O fator A foi a condição de exposição: 1) exposição dérmica potencial (EDP) - sem nenhuma medida de segurança; 2) exposição com cabina no trator (Cabina); e 3) exposição com as vestimentas (EPI). O fator B foi o volume de aplicação: 1) 200 L ha-1 e 2) 100 L ha-1; e o fator C foi o período de aplicação: 1) diurno e 2) noturno. Como testemunha foi avaliada a EDP do tratorista aplicando na atividade usual de 300 L de calda ha-1, no período diurno. As exposições dérmicas (EDs) aos herbicidas considerados nessas condições de trabalho foram estimadas por meio de dados substitutos das EDs avaliadas ao cátion Cu+2 adicionado como traçador nas caldas aplicadas. O pulverizador utilizado foi do modelo PJ 600, com barra de 12 m de comprimento e 24 bicos de jato plano TT 110 04 ou TT 110 02. As 13 condições de trabalho avaliadas foram classificadas como seguras (MS>1) para o tratorista aplicando os herbicidas glyphosate (48% i.a.), MSMA (48%), diuron (46,8%) + hexazinone (13,2%), clomazone (50%), sulfentrazone (50%), ametryne (50%), diuron (50%), isoxaflutole (75%), metribuzin (48%), 2,4-D (80,6%), ametryne (30%) + clomazone (20%), ametryne (73,25%) + trifloxysulfuron (1,85%) e tebuthiuron (80 %) e inseguras para o herbicida atrazine (50%), nos dois períodos e nos três volumes de aplicação, e ametryne (50%), na aplicação diurna e 100 L de calda ha-1. As aplicações noturnas e os volumes de aplicação reduzidos tornaram as condições de trabalho mais seguras, exceto para o atrazine. A eficiência dos EPIs para a aplicação de 300 L ha-1 variou de 69,5 a 89,3%, e a da cabina do trator variou entre 76,4 e 83,3%, em relação aos volumes reduzidos de 100 e 200 L ha-1.pt
dc.description.abstractThis work aimed to evaluate the effects of herbicide application period and volume on the safety of tractor drivers applying herbicide on sugar cane crops using a boom sprayer set and the efficiency of individual protective equipment (IPE), and of a cabin coupled to the tractor. Dermal exposure under thirteen working conditions was evaluated and statistically analyzed in a randomized complete design and a 3 x 2 x 2 + 1 factorial scheme. Factor A constituted the exposure conditions: 1) potential dermal exposure (PDE) - without safety measures; 2) tractor cabin exposure (Cabin) and 3) exposure with clothes on. Factor B constituted volume applications: 1) 200 L ha-1 and 2) 100 L ha-1 and factor C constituted the periods of application: 1) day and 2) night. As control, the tractor driver's PDE was evaluated by applying 300 L ha-1 during the day. Dermal exposure (DE) to the herbicides utilized under these working conditions was calculated by substituted data of the SEs evaluated to the cation Cu+2 added to the mixture, as a tracer. The sprayer was a PJ 600 model, with 12 m long bar and 24 Teejet TT 110 04 or TT 110 02 nozzles. The thirteen working conditions evaluated were classified as safe to the tractor driver applying the herbicides glyphosate (48% ia), MSMA (48%), diuron (46.8%) + hexazinone (13.2%), clomazone (50%), sulfentrazone (50%), ametryne (50%), diuron (50%), isoxaflutole (75%), metribuzin (48%), 2,4 D (80.6%), ametryne (30%) + clomazone (20%), ametryne (73.25%) + trifloxysulfuron (1.85%), tebuthiuron (80 %) and as not safe, applying the atrazine herbicide (50%) during the day, and 100 L ha-1. Night applications and reduced application volumes provided safer work conditions , except for atrazine. IPE efficiency for the 300 L ha-1 applications was around 69.5% and 89.3% and 76.4% to 83.3% for the tractor cabin, compared to the reduced volumes of 100 and 200 L ha-1 .en
dc.format.extent467-478-
dc.language.isopor-
dc.publisherSociedade Brasileira da Ciência das Plantas Daninhas-
dc.sourceSciELO-
dc.subjectDermal Exposureen
dc.subjecttractor driveren
dc.subjectHerbicidesen
dc.subjecttime application and volume applicationen
dc.subjectExposição dérmicapt
dc.subjecttratoristapt
dc.subjectherbicidapt
dc.subjectperíodo de pulverizaçãopt
dc.subjectvolume de pulverizaçãopt
dc.titleEfeitos do período e volume de aplicação na segurança dos tratoristas aplicando herbicidas na cultura de cana-de-açúcar (Saccharum spp.)pt
dc.title.alternativeEffects of herbicide spraying period and volume on the safety of tractor drivers spraying herbicides on sugarcane (Saccharum spp.) cropen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias-
dc.description.affiliationUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias Dep. de Fitossanidade-
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias-
dc.description.affiliationUnespUniversidade Estadual Paulista Faculdade de Ciências Agrárias e Veterinárias Dep. de Fitossanidade-
dc.identifier.doi10.1590/S0100-83582003000300016-
dc.identifier.scieloS0100-83582003000300016-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-83582003000300016.pdf-
dc.relation.ispartofPlanta Daninha-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.