You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25069
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBortolin, José Ricardo Melges-
dc.contributor.authorMalagutti Filho, Walter-
dc.date.accessioned2013-09-30T20:04:44Z-
dc.date.accessioned2014-05-20T14:16:53Z-
dc.date.accessioned2016-10-25T17:39:42Z-
dc.date.available2013-09-30T20:04:44Z-
dc.date.available2014-05-20T14:16:53Z-
dc.date.available2016-10-25T17:39:42Z-
dc.date.issued2010-12-01-
dc.identifierhttp://dx.doi.org/10.1590/S1413-41522010000400009-
dc.identifier.citationEngenharia Sanitaria e Ambiental . ABES , v. 15, n. 4, p. 367-374, 2010.-
dc.identifier.issn1413-4152-
dc.identifier.urihttp://hdl.handle.net/11449/25069-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25069-
dc.description.abstractEste trabalho apresenta os resultados do monitoramento temporal da pluma de contaminação do aterro controlado de Rio Claro, São Paulo, por meio do método da eletrorresistividade, que consistiu na comparação dos resultados de várias seções de imageamento elétrico, executados nos mesmo locais, nos anos de 1999 e 2008. Zonas de baixa resistividade, com valores menores ou iguais a 50 Ω.m, foram associadas à contaminação por chorume. Desse modo, foi possível identificar dois sentidos do fluxo da pluma: (1) em direção ao sul, e (2) em direção ao oeste. Nas seções de 2008, a pluma de contaminação apresentou-se mais extensa e profunda do que em 1999. de forma complementar, as sondagens elétricas verticais aferiram a profundidade do nível freático e o sentido do fluxo d'água, subsidiando a interpretação dos imageamentos.pt
dc.description.abstractThis paper shows the results of a periodical monitoring of the contamination plume of a controlled landfill in Rio Claro, São Paulo, Brazil, using electrical resistivity geophysical method. The monitoring consisted on comparing the results of several electrical sections, performed at the same location, in the years of 1999 and 2008. Low resistivity zones, with values lower than or equal to 50 Ω.m, have been associated to contamination by leachate. Thus, it was possible to identify two directions for the contamination flows: (1) toward south, and (2) toward west. In the results of 2008, the contamination plume was more extensive and profound than in 1999. The vertical electrical soundings indicated the water table depth and the water flow directions, helping the interpretation of results of the electrical profiles.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent367-374-
dc.language.isopor-
dc.publisherABES-
dc.sourceSciELO-
dc.subjectsondagem elétrica verticalpt
dc.subjectimageamento elétricopt
dc.subjectaterropt
dc.subjectchorumept
dc.subjectvertical electrical soundingen
dc.subjectelectrical profileen
dc.subjectlandfillen
dc.subjectleachateen
dc.titleMétodo da eletrorresistividade aplicado no monitoramento temporal da pluma de contaminação em área de disposição de resíduos sólidos urbanospt
dc.title.alternativeElectrical resistivity method applied in the temporal monitoring of the contamination plume in disposal area of urban solid wasteen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUnesp Instituto de Geociências e Ciências Exatas-
dc.description.affiliationUnespUnesp Instituto de Geociências e Ciências Exatas-
dc.identifier.doi10.1590/S1413-41522010000400009-
dc.identifier.scieloS1413-41522010000400009-
dc.identifier.wosWOS:000288498900008-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1413-41522010000400009.pdf-
dc.relation.ispartofEngenharia Sanitária e Ambiental-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.