You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25085
Full metadata record
DC FieldValueLanguage
dc.contributor.authorda Costa Silva, Robson Willians-
dc.contributor.authorMalagutti Filho, Walter-
dc.date.accessioned2013-09-30T18:51:11Z-
dc.date.accessioned2014-05-20T14:16:58Z-
dc.date.accessioned2016-10-25T17:39:44Z-
dc.date.available2013-09-30T18:51:11Z-
dc.date.available2014-05-20T14:16:58Z-
dc.date.available2016-10-25T17:39:44Z-
dc.date.issued2012-07-01-
dc.identifierhttp://dx.doi.org/10.1007/s12665-011-1347-7-
dc.identifier.citationEnvironmental Earth Sciences. New York: Springer, v. 66, n. 5, p. 1371-1383, 2012.-
dc.identifier.issn1866-6280-
dc.identifier.urihttp://hdl.handle.net/11449/25085-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25085-
dc.description.abstractThis paper presents the results of electrical resistivity methods in the area delineation that was potentially contaminated by liquefaction products, which are also called putrefactive liquids in Vila Rezende municipal cemetery, Piracicaba, So Paulo, Brazil. The results indicate a depth of water table between 3.1 and 5.1 m, with two groundwater direction flows, one to the SW and another to the SE. Due to the contamination plumes, which have the same groundwater direction flow, as well the conductive anomalies observed in the geoelectric sections, the contamination suspicions in the area were confirmed. The probable plume to the SE extends beyond the limits of the cemetery. The location of the conductive anomalies and the probable contamination plumes showed that the contamination is linked with the depth of the water table and the burial time. Mapping using the geostatistical method of ordinary kriging applied to the work drew structural characteristics of the regional phenomenon and spatial behavior of the electrical resistivity data, resulting in continued surfaces. Thus, this method has proved to be an important tool for mapping contamination plumes in cemeteries.en
dc.format.extent1371-1383-
dc.language.isoeng-
dc.publisherSpringer-
dc.sourceWeb of Science-
dc.subjectCemeteriesen
dc.subjectElectrical resistivityen
dc.subjectContamination plumeen
dc.subjectGeostatisticsen
dc.subjectOrdinary krigingen
dc.titleGeoelectrical mapping of contamination in the cemeteries: the case study in Piracicaba, São Paulo/Brazilen
dc.typeoutro-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniv São Paulo, CENA, Lab Ecol Isotop, BR-13416000 Piracicaba, SP, Brazil-
dc.description.affiliationUniv Estadual Paulista, Dept Geol Aplicada, Rio Claro, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Dept Geol Aplicada, Rio Claro, SP, Brazil-
dc.identifier.doi10.1007/s12665-011-1347-7-
dc.identifier.wosWOS:000305214900009-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofEnvironmental Earth Sciences-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.