Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/25380
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Guilemany, J. M. | - |
dc.contributor.author | Fernandez, J. | - |
dc.contributor.author | Espallargas, N. | - |
dc.contributor.author | Suegama, P. H. | - |
dc.contributor.author | Benedetti, Assis Vicente | - |
dc.date.accessioned | 2014-05-20T14:17:56Z | - |
dc.date.accessioned | 2016-10-25T17:40:14Z | - |
dc.date.available | 2014-05-20T14:17:56Z | - |
dc.date.available | 2016-10-25T17:40:14Z | - |
dc.date.issued | 2006-02-08 | - |
dc.identifier | http://dx.doi.org/10.1016/j.surfcoat.2005.02.116 | - |
dc.identifier.citation | Surface & Coatings Technology. Lausanne: Elsevier B.V. Sa, v. 200, n. 9, p. 3064-3072, 2006. | - |
dc.identifier.issn | 0257-8972 | - |
dc.identifier.uri | http://hdl.handle.net/11449/25380 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/25380 | - |
dc.description.abstract | Stainless steel coatings obtained by High Velocity Oxygen Fuel (HVOF) were characterized using optical (OM) and scanning electron microscopy (SEM), electron probe micro-analysis, X-ray diffraction (XRD), open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarisation tests. Differences among coated steels were mainly related with the gun-substrate distance parameter (310 nm for samples A and B and 260 min for C and D). The open-circuit potential values measured for all the samples after 18 h of immersion in aerated and unstirred 3.4% NaCl solution were: - 0.334, - 0.360, - 0.379 and - 0.412 V vs. Ag/AgCl,KClsat. for samples A to D, respectively. For EIS measurements, Nyquist plots showed higher capacitive semi-circle for samples sprayed at longer distance, indicating higher corrosion resistance in NaCl solution. (c) 2005 Elsevier B.V. All rights reserved. | en |
dc.format.extent | 3064-3072 | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | HVOF | pt |
dc.subject | stainless steel | pt |
dc.subject | thermal spraying | pt |
dc.subject | corrosion | pt |
dc.subject | electrochemical behaviour | pt |
dc.title | Influence of spraying parameters on the electrochemical behaviour of HVOF thermally sprayed stainless steel coatings in 3.4% NaCl | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, UNESP, Dept Quim Fis, BR-14801970 Araraquara, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, UNESP, Dept Quim Fis, BR-14801970 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1016/j.surfcoat.2005.02.116 | - |
dc.identifier.wos | WOS:000235254000030 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Surface & Coatings Technology | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.