You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25742
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCaldas, Naise Mary-
dc.contributor.authorRaposo, Jorge Luiz-
dc.contributor.authorOliveira, Silvana Ruella-
dc.contributor.authorGomes Neto, José Anchieta-
dc.contributor.authorBarbosa, Fernando-
dc.date.accessioned2014-05-20T14:19:04Z-
dc.date.accessioned2016-10-25T17:40:51Z-
dc.date.available2014-05-20T14:19:04Z-
dc.date.available2016-10-25T17:40:51Z-
dc.date.issued2009-07-01-
dc.identifierhttps://getinfo.de/app/Direct-and-Simultaneous-Determination-of-Cd-Cu/id/BLSE%3ARN256758001-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 30, n. 4, p. 115-119, 2009.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/25742-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25742-
dc.description.abstractA graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO3 + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L-1 Pd(NO3)(2) + 3 mu L of 1000 mg L-1 Mg(NO3)(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L-1 Cd, 0.075 mu g L-1 Cu and 0.3 mu g L-1 Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L-1 Cd, 700 to 921.7 mu g L-1 Cu, and from 68.6 to 350 mu g L-1 Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent115-119-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleDirect and Simultaneous Determination of Cd Cu, and Se in Blood Samples by Graphite Furnace Atomic Absorption Spectrometryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionPiaui Fed Univ-
dc.contributor.institutionUniversidade de São Paulo (USP)-
dc.description.affiliationUNESP, Inst Chem, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationPiaui Fed Univ, Dept Chem, BR-64049550 Teresina, PI, Brazil-
dc.description.affiliationUniv São Paulo, Fac Pharmaceut Sci Ribeirao Preto, BR-14040903 Ribeirao Preto, Brazil-
dc.description.affiliationUnespUNESP, Inst Chem, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000269328100001-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.