You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25774
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRaposo, Jorge Luiz-
dc.contributor.authorOliveira, Silvana Ruella-
dc.contributor.authorGomes Neto, José Anchieta-
dc.contributor.authorNobrega, Joaquim Araujo-
dc.contributor.authorJones, Bradley Todd-
dc.date.accessioned2014-05-20T14:19:09Z-
dc.date.accessioned2016-10-25T17:40:55Z-
dc.date.available2014-05-20T14:19:09Z-
dc.date.available2016-10-25T17:40:55Z-
dc.date.issued2011-01-01-
dc.identifierhttp://dx.doi.org/10.1080/00032719.2010.546025-
dc.identifier.citationAnalytical Letters. Philadelphia: Taylor & Francis Inc, v. 44, n. 12, p. 2150-2161, 2011.-
dc.identifier.issn0003-2719-
dc.identifier.urihttp://hdl.handle.net/11449/25774-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25774-
dc.description.abstractThe least-squares background correction (LSBC) and internal standardization procedures were combined to eliminate spectral interferences caused by the CS molecular band (251.602 nm) and transport effects for determining Si in sulfuric acid digests of lubricant oil by high-resolution continuum source flame atomic absorption spectrometry. Aluminum, Ba, Ti, V, and W were tested as internal standard (IS) candidates, and W provided the best results. For absorbance measurements of solutions containing 0.5-5.0 mg L-1 Si in the presence of 25 mg L-1 W (at the wavelength integrated absorbance equivalent to 3 pixels), the correlation coefficient for the ratio of absorbance of Si to absorbance of W vs. analyte concentration was 0.9978. Fluctuations in analytical signals due to variations in sulfuric acid concentrations or acetylene/nitrous oxide flow-rate ratios were corrected by using this calibration plot. Relative standard deviations varied from 1.9 to 7.2% and 2.1 to 5.4% (n=12) with and without LSBC/IS, respectively. Recoveries for samples spiked with 2.0 mg L-1 Si in 5.0% (v/v) sulfuric acid were within the 72.5-82.5% and 94.0-99.0% ranges without correction and by LSBC associated with internal standardization procedure, respectively. Accuracy of the proposed method was checked for the determination of Si in commercial lubricant oils and results obtained with internal standardization were better than those without correction.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent2150-2161-
dc.language.isoeng-
dc.publisherTaylor & Francis Inc-
dc.sourceWeb of Science-
dc.subjectHigh-resolution continuum source atomic absorption spectrometryen
dc.subjectInternal standardizationen
dc.subjectLubricant oilen
dc.subjectSiliconen
dc.titleDETERMINATION of SILICON IN LUBRICANT OIL BY HIGH-RESOLUTION CONTINUUM SOURCE FLAME ATOMIC ABSORPTION SPECTROMETRY USING LEAST-SQUARE BACKGROUND CORRECTION and INTERNAL STANDARDIZATIONen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.contributor.institutionWake Forest Univ-
dc.description.affiliationUNESP Univ Estadual Paulista, Dept Analyt Chem, Araraquara, SP, Brazil-
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar), Dept Chem, BR-13560 São Carlos, SP, Brazil-
dc.description.affiliationWake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA-
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Dept Analyt Chem, Araraquara, SP, Brazil-
dc.identifier.doi10.1080/00032719.2010.546025-
dc.identifier.wosWOS:000294602900008-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAnalytical Letters-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.