You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25787
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFerreira, Roberta Borges-
dc.contributor.authorOliveira, Silvana Ruella-
dc.contributor.authorFranzini, Vanessa Pezza-
dc.contributor.authorVirgilio, Alex-
dc.contributor.authorRaposo Junior, Jorge Luiz-
dc.contributor.authorGomes Neto, José Anchieta-
dc.date.accessioned2014-05-20T14:19:12Z-
dc.date.accessioned2016-10-25T17:40:56Z-
dc.date.available2014-05-20T14:19:12Z-
dc.date.available2016-10-25T17:40:56Z-
dc.date.issued2011-03-01-
dc.identifierhttp://jglobal.jst.go.jp/public/20090422/201202230103386562-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 32, n. 2, p. 56-61, 2011.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/25787-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25787-
dc.description.abstractThe usefulness of the side pixel registration approach and molecular absorption was investigated for the determination of phosphorus (P) and potassium (K) in liquid fertilizers by high-resolution continuum source flame atomic absorption spectrometry.The phosphorus oxide (PO) lines at 246.400 nm, 247.620 nm, 247.780 nm, 324.616 nm, and 327.040 nm were evaluated. The influence of side pixel registration to extend the linear working range was also investigated by measuring at wings (404.402 nm, 404.406 nm, 404.410 nm, 404.418 nm, 404.422 nm and 404.426 nm) of the secondary line for K at 404.414 nm. For the lines 327.040 mm and 404.422 nm, analytical curves in the 100-5000 mg L-1 and 50-1000 mg L-1 ranges were obtained with linear correlations better than 0.999 and 0.995, respectively.The proposed method was applied to six liquid fertilizer samples. The found concentrations for K and P were in agreement with those obtained by inductively coupled plasma optical emission spectrometry (ICP-OES), spectrophotometry, and flame atomic emission spectrometry at the 95% confidence level.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent56-61-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleEvaluation of Lines of Phosphorus and Potassium by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry for Liquid Fertilizer Analysisen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Univ Estadual Paulista, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil-
dc.description.sponsorshipIdCNPq: 300600/2009-7-
dc.identifier.wosWOS:000289743800002-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.