Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/25839
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Uliana, Carolina V. | - |
dc.contributor.author | Riccardi, Carla S. | - |
dc.contributor.author | Tognolli, Joao O. | - |
dc.contributor.author | Yamanaka, Hideko | - |
dc.date.accessioned | 2014-05-20T14:19:21Z | - |
dc.date.accessioned | 2016-10-25T17:41:02Z | - |
dc.date.available | 2014-05-20T14:19:21Z | - |
dc.date.available | 2016-10-25T17:41:02Z | - |
dc.date.issued | 2008-01-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S0103-50532008000400024 | - |
dc.identifier.citation | Journal of The Brazilian Chemical Society. São Paulo: Soc Brasileira Quimica, v. 19, n. 4, p. 782-787, 2008. | - |
dc.identifier.issn | 0103-5053 | - |
dc.identifier.uri | http://hdl.handle.net/11449/25839 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/25839 | - |
dc.description.abstract | Fractional factorial design and factorial with center point design were applied to the development of an amperometric biosensor for the detection of the hepatitis C virus. Biomolecules were immobilized by adsorption on graphite electrodes modified with siloxane-poly(propyleneoxide) hybrid matrix prepared using the sol-gel method. Several parameters were optimized, such as the streptavidin concentration at 0.01 mg mL(-1) and 1.0% bovine serum albumin, the incubation time of the electrodes in the complementary DNA solution for 30 minutes and a 1: 1500 dilution of the avidin-peroxidase conjugate, among others. The application of chemometric studies has been efficient, since the best conditions have been established with a restricted number of experiments, indicating the influence of different factors on the system. | en |
dc.format.extent | 782-787 | - |
dc.language.iso | eng | - |
dc.publisher | Soc Brasileira Quimica | - |
dc.source | Web of Science | - |
dc.subject | biosensor | en |
dc.subject | hepatitis C virus | en |
dc.subject | fractional factorial design | en |
dc.title | Optimization of an amperometric biosensor for the detection of hepatitis C virus using fractional factorial designs | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, BR-14800900 Araraquara, SP, Brazil | - |
dc.identifier.doi | 10.1590/S0103-50532008000400024 | - |
dc.identifier.scielo | S0103-50532008000400024 | - |
dc.identifier.wos | WOS:000256957100023 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.relation.ispartof | Journal of the Brazilian Chemical Society | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.