You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25853
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGarbellini, Gustavo S.-
dc.contributor.authorUliana, Carolina V.-
dc.contributor.authorYamanaka, Hideko-
dc.date.accessioned2014-05-20T14:19:24Z-
dc.date.accessioned2016-10-25T17:41:04Z-
dc.date.available2014-05-20T14:19:24Z-
dc.date.available2016-10-25T17:41:04Z-
dc.date.issued2011-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0103-50532011000700007-
dc.identifier.citationJournal of The Brazilian Chemical Society. São Paulo: Soc Brasileira Quimica, v. 22, n. 7, p. 1241-1245, 2011.-
dc.identifier.issn0103-5053-
dc.identifier.urihttp://hdl.handle.net/11449/25853-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25853-
dc.description.abstractThe individual detection and equimolar mixture of DNA nucleotides guanosine monophosphate (GMP), adenosine monophosphate (AMP), thymidine (TMP) and cytidine (CMP) 5'-monophosphate using square wave voltammetry was performed on boron doped diamond (BDD) electrodes cathodically (Red-DDB) and anodically (Oxi-DDB) pretreated. The oxidation of individual DNA nucleotides was more sensitive on Oxi-BDD electrode. In a simultaneous detection of nucleotides, the responses of GMP, AMP, TMP and CMP were very adequate on both treated electrodes. Particularly, more sensitive and separate peaks for TMP and CMP on Oxi-BDD and Red-BDD electrodes, respectively, were observed after deconvolution procedure. The detection of nucleotides in aqueous solutions will certainly contribute for genotoxic evaluation of substances and hybridization reactions by immobilizing ss or ds-DNA on BDD surface.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.format.extent1241-1245-
dc.language.isoeng-
dc.publisherSoc Brasileira Quimica-
dc.sourceWeb of Science-
dc.subjectDNAen
dc.subjectnucleotidesen
dc.subjectdiamond electrodesen
dc.subjectsurface terminationen
dc.titleDetection of DNA Nucleotides on Pretreated Boron Doped Diamond Electrodesen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationSão Paulo State Univ UNESP, Inst Chem, BR-14800900 Araraquara, SP, Brazil-
dc.description.affiliationUnespSão Paulo State Univ UNESP, Inst Chem, BR-14800900 Araraquara, SP, Brazil-
dc.description.sponsorshipIdFAPESP: 09/08161-8-
dc.description.sponsorshipIdFAPESP: 08/08990-1-
dc.identifier.doi10.1590/S0103-50532011000700007-
dc.identifier.scieloS0103-50532011000700007-
dc.identifier.wosWOS:000293388500007-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofJournal of the Brazilian Chemical Society-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.