You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25881
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFreschi, Gian Paulo G.-
dc.contributor.authorFreschi, Carolina D.-
dc.contributor.authorGomes Neto, José Anchieta-
dc.date.accessioned2014-05-20T14:19:29Z-
dc.date.accessioned2016-10-25T17:41:06Z-
dc.date.available2014-05-20T14:19:29Z-
dc.date.available2016-10-25T17:41:06Z-
dc.date.issued2009-09-01-
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 30, n. 5, p. 147-155, 2009.-
dc.identifier.issn0195-5373-
dc.identifier.urihttp://hdl.handle.net/11449/25881-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25881-
dc.description.abstractDifferent kinds of ruthenium coatings are proposed as chemical modifiers for the simultaneous determination of two groups of elements: first, the more Volatile elements Such as As, Bi, Pb, Sb, and Se and, second, the elements Co, Cr, Cu, Fe, and Mn in milk samples by electrothermal atomic absorption spectrometry. Uncoated and coated platforms tube with Ru modifiers and co-injection of Pd+Mg were Studied. Milk samples were 1 + 9 diluted in 1.0% (v/v) HNO(3) an injected into the tube. Very long tube lifetimes were obtained for the two groups with around 750 cycles for the direct determination of the diluted milk sample. Platforms, pretreated with W-Ru, were selected for the first group and pretreated platforms with W plus RuCl(3) were selected for the second group. Calibration by matrix matching and analytical curves in the 5.0 - 20.0 mu g L(-1) range with good linear correlation coefficients were obtained. Relative standard deviations were 7.2% and the calculated characteristic masses were between 7.2 pg and 89.1 pg. The limits of detection obtained for undiluted milk samples were as follows:For Group I elements:32 mu g L(-1) for As; 36 mu g L(-1) for Bi; 29 mu g L(-1) for Se; 29 mu g L(-1) for Sb; 25 mu g L(-1) for Pb; 18 mu g L(-1) for Co.For Group 2 elements:13 mu g L(-1) for Cr; 16 mu g L(-1) for Cu; 53 mu g L(-1) for Fe; 20 mu g L(-1) for Mn.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent147-155-
dc.language.isoeng-
dc.publisherPerkin-elmer Corp-
dc.sourceWeb of Science-
dc.titleSimultaneous Determination of Two Groups of Elements in Milk by Electrothermal Atomic Absorption Spectrometry: Evaluation of Ruthenium Modifiersen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal da Grande Dourados (UFGD)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationFundação Univ Fed Grande Dourados, Fac Ciencias Exatas & Tecnol, BR-79804970 Dourados, MS, Brazil-
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil-
dc.identifier.wosWOS:000272362300001-
dc.rights.accessRightsAcesso restrito-
dc.relation.ispartofAtomic Spectroscopy-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.