Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/25882
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Santos, Luana Novaes | - |
dc.contributor.author | Gomes Neto, José Anchieta | - |
dc.contributor.author | Caldas, Naise Mary | - |
dc.date.accessioned | 2014-05-20T14:19:29Z | - |
dc.date.accessioned | 2016-10-25T17:41:07Z | - |
dc.date.available | 2014-05-20T14:19:29Z | - |
dc.date.available | 2016-10-25T17:41:07Z | - |
dc.date.issued | 2012-09-01 | - |
dc.identifier | http://dx.doi.org/10.1016/j.fuel.2012.04.024 | - |
dc.identifier.citation | Fuel. Oxford: Elsevier B.V., v. 99, p. 9-12, 2012. | - |
dc.identifier.issn | 0016-2361 | - |
dc.identifier.uri | http://hdl.handle.net/11449/25882 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/25882 | - |
dc.description.abstract | A method has been developed for the simultaneous determination of Cu and Pb in ethanol fuel by GF AAS using a transversely heated graphite atomizer (THGA) with W permanent modifier and co-injection of Ir. Pyrolysis and atomization temperature curves were established in fuel ethanol medium (1 + 1; v/v) containing 1.0% (v/v) HNO3 and spiked with 20 mu g L-1 Cu and Pb. For 20 mu L of diluted sample (10 mu L ethanol + 10 mu L of 2.0 % (v/v) HNO3) dispensed into the graphite tube, analytical curves in the 5.0-25 mu g L-1 Cu and 10-50 mu g L-1 Pb ranges were established. The calculated characteristic masses were 18 pg for Cu and 36 pg for Pb. The limits of detection (LOD) based on integrated absorbance were 0.086 mu g L-1 and 2.47 mu g L-1 for Cu and Pb, respectively. The recoveries of the spiked samples varied from 93-103% (Cu) and 96-110% (Pb). The relative standard derivations (n = 12) were <= 0.5 Cu and <= 0.7 Pb. Accuracy was checked for Cu and Pb determination in 10 samples purchased at local gas stations in Brazil. The found concentrations varied from 8.0 to 47 mu g L-1 Cu. All the analyzed samples presented Pb contents below the limit of detection of this method. These amounts are considered acceptable for the Brazilian regulatory agency for hydrated fuel ethanol. (C) 2012 Elsevier Ltd. All rights reserved. | en |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | - |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | - |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado da Bahia (FAPESB) | - |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.source | Web of Science | - |
dc.subject | Hydrated ethanol fuel | en |
dc.subject | GF AAS | en |
dc.subject | Modifiers | en |
dc.subject | Tungsten | en |
dc.subject | Iridium | en |
dc.title | Simultaneous determination of Cu and Pb in fuel ethanol by graphite furnace AAS using tungsten permanent modifier with co-injection of Ir | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Federal do Piauí (UFPI) | - |
dc.contributor.institution | Univ Estadual Sudoeste Bahia | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.description.affiliation | Univ Fed Piaui, BR-6480000 Floriano, Piaui, Brazil | - |
dc.description.affiliation | Univ Estadual Sudoeste Bahia, Lab Quim Analit, BR-45200190 Jequie, BA, Brazil | - |
dc.description.affiliation | Univ Estadual Paulista, Dept Quim Analit, BR-14801970 São Paulo, Brazil | - |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Quim Analit, BR-14801970 São Paulo, Brazil | - |
dc.identifier.doi | 10.1016/j.fuel.2012.04.024 | - |
dc.identifier.wos | WOS:000305150900002 | - |
dc.rights.accessRights | Acesso restrito | - |
dc.relation.ispartof | Fuel | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.