You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25931
Full metadata record
DC FieldValueLanguage
dc.contributor.authorOliveira, Adriana Paiva de-
dc.contributor.authorOkumura, Leonardo Luiz-
dc.contributor.authorGomes Neto, José Anchieta-
dc.contributor.authorMoraes, Mercedes de-
dc.date.accessioned2014-05-20T14:19:41Z-
dc.date.accessioned2016-10-25T17:41:13Z-
dc.date.available2014-05-20T14:19:41Z-
dc.date.available2016-10-25T17:41:13Z-
dc.date.issued2002-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-46702002000200024-
dc.identifier.citationEclética Química. Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP, v. 27, n. spe, p. 285-291, 2002.-
dc.identifier.issn0100-4670-
dc.identifier.urihttp://hdl.handle.net/11449/25931-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25931-
dc.description.abstractO método empregado para a determinação de sódio por espectrometria de emissão atômica em chama, foi o das adições de analito sendo as intensidades de emissão representadas em função das concentrações de analito adicionadas às várias porções da amostra, numa faixa linear de 0 - 0,300 mg Na L-1, empregando-se 2,1 g K L-1 como supressor de ionização. Foram analisadas 20 amostras comerciais de álcool etílico hidratado combustível (AEHC), coletadas em diferentes postos de abastecimento, na cidade de Araraquara e os resultados obtidos encontram-se no intervalo, desde menor que o limite de detecção (0,0072 mg Na L-1) até 1,55 mg Na L-1. Os limites de detecção referentes à determinação de sódio em cada amostra situam-se entre 0,0026 e 0,0239 mg Na L-1. A porcentagem de recuperação variou no intervalo de 95 a 104 %. Os desvios padrão relativos (n=12) foram £ 4,1 % para as três adições de analito, nas 20 amostras de AEHC.pt
dc.description.abstractThe analyte additions method was applied for sodium determination in fuel ethanol by atomic emission spectrometry. Graphics involving emission intensity versus analyte concentration in the 0 - 0.300 mg Na L-1 interval concentration range contaning 2.1 g K L-1 as an ionisation buffer. Twenty samples of commercial fuel ethanol were collected in differents gas stations located in Araraquara city, analyzed and results obtained varied from 0.0072 to 1.55 mg Na L-1. The limits of detecction (L.O.D.) varied from 0.0026 to 0.0239 mg Na L-1. Recoveries varied in the 95 - 104 % interval. The relative standard deviations (n=12) for three analyte additions in all samples were £ 4,1 %.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent285-291-
dc.language.isopor-
dc.publisherEditora Unesp-
dc.sourceSciELO-
dc.subjectEspectrometria de emissão atômica em chamapt
dc.subjectmétodo das adições de analitopt
dc.subjectálcool combustívelpt
dc.subjectdeterminação de sódiopt
dc.subjectFlame atomic emission spectrometryen
dc.subjectanalyte additions methoden
dc.subjectfuel ethanolen
dc.subjectsodiumen
dc.titleAvaliação do método das adições de analito para a determinação de sódio em álcool combustível por espestrometria de emissão atômica em chamapt
dc.title.alternativeEvaluation of analyte additions method for sodium determination in fuel ethanol by flame atomic emission spectrometryen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Instituto de Química de Araraquara Departamento de Química Analítica-
dc.description.affiliationUnespUNESP Instituto de Química de Araraquara Departamento de Química Analítica-
dc.identifier.doi10.1590/S0100-46702002000200024-
dc.identifier.scieloS0100-46702002000200024-
dc.rights.accessRightsAcesso aberto-
dc.relation.ispartofEclética Química-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.