You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25939
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGomes Neto, José Anchieta-
dc.contributor.authorSilva, José Bento B.-
dc.contributor.authorRodrigues Neto, Renato-
dc.contributor.authorCurtius, Adilson José-
dc.contributor.authorSouza, Ivan G.-
dc.date.accessioned2014-05-20T14:19:43Z-
dc.date.accessioned2016-10-25T17:41:14Z-
dc.date.available2014-05-20T14:19:43Z-
dc.date.available2016-10-25T17:41:14Z-
dc.date.issued1998-07-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-40421998000400005-
dc.identifier.citationQuímica Nova. Sociedade Brasileira de Química, v. 21, n. 4, p. 405-409, 1998.-
dc.identifier.issn0100-4042-
dc.identifier.urihttp://hdl.handle.net/11449/25939-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25939-
dc.description.abstractAn automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent405-409-
dc.language.isopor-
dc.publisherSociedade Brasileira de Química-
dc.sourceSciELO-
dc.subjectpneumatic nebulizersen
dc.subjectICP-MSen
dc.subjecton-line dilutionen
dc.titleEmprego de nebulizador pneumático de ICP-MS como câmara de diluição em sistemas de injeção em fluxo para determinações multielementarespt
dc.title.alternativePneumatic nebulizer as a dilution chamber in a flow-injection system for multielement analysis by ICP-MSen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionUniversidade Federal de Santa Catarina (UFSC)-
dc.description.affiliationUniversidade Estadual Paulista Instituto de Química Departamento de Química Analítica-
dc.description.affiliationUniversidade Federal de Santa Catarina Departamento de Química-
dc.description.affiliationUnespUniversidade Estadual Paulista Instituto de Química Departamento de Química Analítica-
dc.identifier.doi10.1590/S0100-40421998000400005-
dc.identifier.scieloS0100-40421998000400005-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-40421998000400005.pdf-
dc.relation.ispartofQuímica Nova-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.