You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25940
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPereira, Elisabete A.-
dc.contributor.authorCardoso, Arnaldo Alves-
dc.contributor.authorDasgupta, Parnendu K.-
dc.date.accessioned2014-05-20T14:19:43Z-
dc.date.accessioned2016-10-25T17:41:14Z-
dc.date.available2014-05-20T14:19:43Z-
dc.date.available2016-10-25T17:41:14Z-
dc.date.issued2001-08-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-40422001000400003-
dc.identifier.citationQuímica Nova. Sociedade Brasileira de Química, v. 24, n. 4, p. 443-448, 2001.-
dc.identifier.issn0100-4042-
dc.identifier.urihttp://hdl.handle.net/11449/25940-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25940-
dc.description.abstractA sensitive and simple system was proposed for the in situ measurement of total aldehyde in outdoor or indoor ambient. The method is based on the use of a reagent drop as an useful interface to preconcentrate the sample prior to determination of total aldehyde as formaldehyde. The drop is formed at the tip of a cylindrical tube that contains two optical fibers placed on opposite sides and in contact with the reagent solution. One optical fiber carries the red light to the drop form a light emitting diode (LED). The transmitted light is measured by a second optical fiber/photodiode system. The analytical signal is read and converted into absorbance. The reagent solution of 3-methyl-2-benzothiazoline hydrazone (MBTH) forms a blue cation during reaction with formaldehyde that can be measured at 660 nm. Some aspects of kinetics reaction formation of dye were reevaluated. The formaldehyde reacts with MBTH and forms the azine in about 12 min. The oxidation of MBTH by Fe (III) and the formation of dye requires 3 min. The absorbance of the reagent drop is proportional to the sampling time and to the analyte concentration. The absorbance signal increases with increased sample gas flow until a maximum is reached then decreases until it forms a plateau. The proposed method was evaluated using both outdoor and indoor samples, and it was shown to viable provide an accurate measure of total aldehyde.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.format.extent443-448-
dc.language.isopor-
dc.publisherSociedade Brasileira de Química-
dc.sourceSciELO-
dc.subjectaldehydeen
dc.subjectsuspended dropleten
dc.subjectair analysisen
dc.titleGota suspensa para avaliação de aldeído total no ar interno e externo do ambientept
dc.title.alternativeSuspended droplet for evaluation of total aldehyde in outdoor and indoor ambienten
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionTexas Tech Universtiy Department of Chemistry and Biochemistry-
dc.description.affiliationUniversidade Estadual Paulista Instituto de Química Departamento de Química Analítica-
dc.description.affiliationTexas Tech Universtiy Department of Chemistry and Biochemistry-
dc.description.affiliationUnespUniversidade Estadual Paulista Instituto de Química Departamento de Química Analítica-
dc.identifier.doi10.1590/S0100-40422001000400003-
dc.identifier.scieloS0100-40422001000400003-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-40422001000400003.pdf-
dc.relation.ispartofQuímica Nova-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.