You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/25968
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTomita, I. N.-
dc.contributor.authorManzoli, A.-
dc.contributor.authorFertonani, Fernando Luís-
dc.contributor.authorYamanaka, Hideko-
dc.date.accessioned2014-05-20T14:19:50Z-
dc.date.accessioned2016-10-25T17:41:18Z-
dc.date.available2014-05-20T14:19:50Z-
dc.date.available2016-10-25T17:41:18Z-
dc.date.issued2005-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-46702005000200005-
dc.identifier.citationEclética Química. Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP, v. 30, n. 2, p. 37-43, 2005.-
dc.identifier.issn0100-4670-
dc.identifier.urihttp://hdl.handle.net/11449/25968-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/25968-
dc.description.abstractDesenvolveu-se um biossensor para ácido L-ascórbico empregando ascorbato oxidase. A enzima foi extraída do mesocarpo de pepino com solução tampão fosfato 0,05 mol L-1, pH 5,8 contendo NaCl 0,5 mol L-1. Após diálise versus solução tampão fosfato 0,05 mol L-1, pH 5,8 a enzima foi imobilizada em rede de nylon através de ligação covalente com glutaraldeído. A membrana foi acoplada em eletrodo de O2 e a reação monitorada pelo consumo de oxigênio a -600 mV em análise em fluxo (solução tampão fosfato 0,05 mol L-1, pH 5,8 como carregador e vazão 0,5 mL min-1). A curva analítica apresentou-se linear entre 1,2x10-4 a 1,0x10-3 mol L-1. O tempo de vida do biossensor foi de 500 análises. Amostras de medicamentos foram analisadas com a metodologia proposta e os resultados comparados com os obtidos com HPLC.pt
dc.description.abstractA L-ascorbic acid biosensor based on ascorbate oxidase has been developed. The enzyme was extracted from the mesocarp of cucumber (Cucumis sativus) by using 0.05 mol L-1 phosphate buffer, pH 5.8 containing 0.5 mol L-1 NaCl. After the dialysis versus phosphate buffer 0.05 mol L-1 pH 5.8, the enzyme was immobilized onto nylon net through glutaraldehyde covalent bond. The membrane was coupled to an O2 electrode and the yielding reaction monitored by oxygen depletion at -600 mV using flow injection analysis optimized to 0.1 mol L-1 phosphate buffer pH 5.8, as the carrier solution and flow-rate of 0.5 mL min-1. The ascorbic acid calibration curve was linear from 1.2x10-4 to 1.0x10-3 mol L-1. The evaluation of biosensor lifetime leads to 500 injections. Commercial pharmaceutical samples were analyzed with the proposed method and the results were compared with those obtained by high-performance liquid chromatography (HPLC).en
dc.format.extent37-43-
dc.language.isoeng-
dc.publisherEditora Unesp-
dc.sourceSciELO-
dc.subjectbiossensorpt
dc.subjectácido ascórbicopt
dc.subjectanálise por injeção em fluxopt
dc.subjectbiosensoren
dc.subjectascorbic aciden
dc.subjectflow injection analysisen
dc.titleAmperometric biosensor for ascorbic aciden
dc.title.alternativeBiossensor amperométrico para ácido ascórbicopt
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP Instituto de Química Departamento de Química Analítica-
dc.description.affiliationUnespUNESP Instituto de Química Departamento de Química Analítica-
dc.identifier.doi10.1590/S0100-46702005000200005-
dc.identifier.scieloS0100-46702005000200005-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-46702005000200005.pdf-
dc.relation.ispartofEclética Química-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.