Please use this identifier to cite or link to this item:
http://acervodigital.unesp.br/handle/11449/26604
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Niccoli Filho, Walter | - |
dc.contributor.author | Sampaio, Tatiane Alves | - |
dc.contributor.author | Guimarães Filho, Rubens | - |
dc.date.accessioned | 2014-05-20T15:07:38Z | - |
dc.date.accessioned | 2016-10-25T17:42:28Z | - |
dc.date.available | 2014-05-20T15:07:38Z | - |
dc.date.available | 2016-10-25T17:42:28Z | - |
dc.date.issued | 2001-06-01 | - |
dc.identifier | http://dx.doi.org/10.1590/S1517-74912001000200008 | - |
dc.identifier.citation | Pesquisa Odontológica Brasileira. Sociedade Brasileira de Pesquisa Odontológica e Faculdade de Odontologia da Universidade de São Paulo, v. 15, n. 2, p. 127-132, 2001. | - |
dc.identifier.issn | 1517-7491 | - |
dc.identifier.uri | http://hdl.handle.net/11449/26604 | - |
dc.identifier.uri | http://acervodigital.unesp.br/handle/11449/26604 | - |
dc.description.abstract | O laser de dióxido de carbono (CO2), pelas suas propriedades intrínsecas, tem se tornado um instrumento cirúrgico importante; entre estas podemos citar: hemostasia, redução do edema e da dor pós-operatória e esterilização do campo cirúrgico. Seu uso em tecido ósseo para realização de osteotomias ainda é questionável, principalmente devido à possibilidade de iatrogenias causadas pelo aumento da temperatura tecidual, bem como destes efeitos na área paraincisional. O propósito deste estudo foi proporcionar a confecção de um plano piloto visando analisar macroscopicamente os efeitos da radiação laser de CO2 em tíbia de rato a fim de estabelecerem-se parâmetros de segurança quanto a potência. Foram utilizados 12 ratos. Após anestesia, os ossos foram submetidos a radiação com potência de 1, 3 e 5 watts. Os animais foram sacrificados nos tempos imediatamente após, 3, 7 e 14 dias após a irradiação, visando à remoção do osso tratado. Os espécimes obtidos foram observados através de lupa estereoscópica com aumentos de 14, 25 e 40 vezes e fotografados para posterior análise. Os resultados permitiram concluir que a potência de 1 watt proporciona uma melhor qualidade de resposta à reparação e que as potências de 3 e 5 watts provocaram o atraso na cronologia de reparo. | pt |
dc.description.abstract | The use of CO2 laser in osseous tissue to execute osteotomies is still questionable, mainly due to the increase of temperature in the site of irradiation. The purpose of this research was to carry out a pilot study in order to analyze macroscopically the effect of CO2 laser irradiation on rat tibia and to establish security parameters regarding power. Twelve rats were submitted to irradiation with 1, 3 and 5 watts of power and were examined immediately, 3, 7 and 14 days after irradiation. The results showed better healing when irradiation was carried out with the power of 1 watt; the 3- and 5-watt powers caused delay in the chronology of healing. | en |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | - |
dc.format.extent | 127-132 | - |
dc.language.iso | por | - |
dc.publisher | Sociedade Brasileira de Pesquisa Odontológica e Faculdade de Odontologia da Universidade de São Paulo | - |
dc.source | SciELO | - |
dc.subject | Lasers | pt |
dc.subject | Dióxido de carbono | pt |
dc.subject | Potência | pt |
dc.subject | Osso e ossos | pt |
dc.subject | Lasers | en |
dc.subject | Carbon dioxide | en |
dc.subject | Potency | en |
dc.subject | Bone and bones | en |
dc.title | Efeitos da radiação laser de dióxido de carbono em tecido ósseo: estudo macroscópico em ratos | pt |
dc.title.alternative | Effect of carbon dioxide laser radiation on osseous tissue: macroscopic study in rats | en |
dc.type | outro | - |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | - |
dc.contributor.institution | Instituto de Pesquisas Energéticas e Nucleares (IPEN) | - |
dc.contributor.institution | Universidade de São Paulo (USP) | - |
dc.description.affiliation | Universidade Estadual Paulista Faculdade de Odontologia de São José dos Campos Departamento de Biopatologia e Diagnóstico | - |
dc.description.affiliation | Universidade Estadual Paulista Faculdade de Odontologia de São José dos Campos | - |
dc.description.affiliation | IPEN | - |
dc.description.affiliation | Universidade de São Paulo Faculdade de Odontologia | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Faculdade de Odontologia de São José dos Campos Departamento de Biopatologia e Diagnóstico | - |
dc.description.affiliationUnesp | Universidade Estadual Paulista Faculdade de Odontologia de São José dos Campos | - |
dc.description.sponsorshipId | FAPESP: 99/00466-0 | - |
dc.identifier.doi | 10.1590/S1517-74912001000200008 | - |
dc.identifier.scielo | S1517-74912001000200008 | - |
dc.rights.accessRights | Acesso aberto | - |
dc.identifier.file | S1517-74912001000200008.pdf | - |
dc.relation.ispartof | Pesquisa Odontológica Brasileira | - |
dc.identifier.scopus | 2-s2.0-0035320325 | - |
Appears in Collections: | Artigos, TCCs, Teses e Dissertações da Unesp |
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.