You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27021
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMartins, Carlos Henrique-
dc.contributor.authorCastro Júnior, Ney de-
dc.contributor.authorCosta Filho, Orozimbo Alves-
dc.contributor.authorSouza Neto, Osmar Mesquita de-
dc.date.accessioned2014-05-20T15:08:51Z-
dc.date.accessioned2016-10-25T17:43:26Z-
dc.date.available2014-05-20T15:08:51Z-
dc.date.available2016-10-25T17:43:26Z-
dc.date.issued2011-12-01-
dc.identifierhttp://dx.doi.org/10.1590/S1808-86942011000600004-
dc.identifier.citationBrazilian Journal of Otorhinolaryngology. Associação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial, v. 77, n. 6, p. 700-705, 2011.-
dc.identifier.issn1808-8694-
dc.identifier.urihttp://hdl.handle.net/11449/27021-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/27021-
dc.description.abstractA Síndrome da Apneia Obstrutiva do Sono (SAOS) diminui as capacidades da atenção, memória e concentração, fatores relacionados com a cognição. A análise dos parâmetros do P300 auditivo permitiria inferir disfunção cognitiva. OBJETIVO: Comparar os dados da polissonografia e do P300 auditivo em adultos, roncopatas primários com portadores de SAOS. CASUÍSTICA E MÉTODO: Estudo prospectivo em roncopatas primários (N=12) e em portadores de SAOS (N=54), submetidos à polissonografia definidos pelo índice de apneia e hipopneia (IAH). As variáveis da polissonografia e as do P300 foram comparadas, pelos testes T de Student, exato de Fisher, regressão logística e análise de correlação com nível de significância de 5%. RESULTADOS: O IAH apresentou correlação inversa com a oximetria em ambos os grupos. A prevalência do P300 foi menor no G.SAOS (teste exato de Fisher, p=0,027). A idade dos pacientes não influenciou a prevalência do P300 (análise de regressão; p=0,232). A amplitude do P300 foi menor do G.SAOS (teste T de Student; p=0,003) a latência do P300 foi semelhante em ambos os grupos (teste T de Student; p=0,89). CONCLUSÃO: A redução da amplitude do P300 nos portadores de SAOS sugere disfunção cognitiva induzida por diminuição da memória auditiva.pt
dc.description.abstractThe obstructive sleep apnea syndrome (OSAS) reduces attention span, memory and concentration capacities, all associated with cognition. The analysis of the auditory P300 parameters could help infer cognitive dysfunction. OBJECTIVE: To compare the data from polysomnography and the auditory P300 in adults, primary snorers with OSAS patients. MATERIALS and METHODS: Prospective study with primary snorers (N=12) and in OSAS patients (N=54), submitted to polysomnography, defined by the apnea-hypopnea index (AHI). The polysomnography and P300 variables were compared by the t-Student test, the Exact Fisher's Test, logistic regression and analysis of correlation with a significance level of 5%. RESULTS: AIH had an inverse correlation with the oximetry in both groups. The P300 prevalence was lower in the OSAS group (Fisher's Exact Test, p=0.027). Patient age did not influence the P300 prevalence (regression analysis; p=0.232). The P300 amplitude was lower in the OSAS group (t-Student test; p=0.003) and the P300 latency was similar in both groups (t-Student test; p=0.89). CONCLUSION: The reduction in the P300 amplitude in patients with OSAS suggests cognitive dysfunction induced by a reduction in auditory memory.en
dc.description.sponsorshipMedical School of the Sta. Casa de S. Paulo-
dc.format.extent700-705-
dc.language.isopor-
dc.publisherAssociação Brasileira de Otorrinolaringologia e Cirurgia Cervicofacial-
dc.sourceSciELO-
dc.subjectapneia do sono tipo obstrutivapt
dc.subjectcogniçãopt
dc.subjectpotenciais evocados auditivospt
dc.subjectpotencial evocado p300pt
dc.subjecttranstornos respiratóriospt
dc.subjectauditoryen
dc.subjectcognitionen
dc.subjectevent related potentialsen
dc.subjectevoked potentialsen
dc.subjectp300en
dc.subjectobstructiveen
dc.subjectespiration disordersen
dc.subjectsleep apneaen
dc.titleSíndrome da apneia obstrutiva do sono e o potencial auditivo P300pt
dc.title.alternativeObstructive sleep apnea and P300 evoked auditory potentialen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionFCM da Sta.Casa de S. Paulo-
dc.description.affiliationUNESP Fac. de Odontologia Depto. de Fonoaudiologia-
dc.description.affiliationUNESP Fac. de Odontologia de Bauru Depto de Fonoaudiologia-
dc.description.affiliationFCM da Sta.Casa de S. Paulo-
dc.description.affiliationUnespUNESP Fac. de Odontologia Depto. de Fonoaudiologia-
dc.description.affiliationUnespUNESP Fac. de Odontologia de Bauru Depto de Fonoaudiologia-
dc.identifier.doi10.1590/S1808-86942011000600004-
dc.identifier.scieloS1808-86942011000600004-
dc.identifier.wosWOS:000298280300004-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS1808-86942011000600004.pdf-
dc.relation.ispartofBrazilian Journal of Otorhinolaryngology-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.