- Determinação turbidimétrica de dipirona em fluxo utilizando um reator contendo cloreto de prata imobilizado em resina poliéster
- Flow injection turbidimetric determination of dipyrone using a solid-phase reactor containing silver chloride immobilized in a polyester resin
- Universidade Federal de São Carlos (UFSCar)
- Universidade Estadual Paulista (UNESP)
- 0100-4042
- Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
- A simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.
- 1-Oct-2005
- Química Nova. Sociedade Brasileira de Química, v. 28, n. 5, p. 783-787, 2005.
- 783-787
- Sociedade Brasileira de Química
- dipyrone
- flow injection turbidimetry
- solid-phase reactor
- http://dx.doi.org/10.1590/S0100-40422005000500009
- Acesso aberto
- outro
- http://repositorio.unesp.br/handle/11449/27592
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.