You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27592
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMarcolino-Jr., Luiz H.-
dc.contributor.authorBonifácio, Viviane Gomes-
dc.contributor.authorFatibello-Filho, Orlando-
dc.contributor.authorTeixeira, Marcos F. S.-
dc.date.accessioned2014-05-20T15:10:20Z-
dc.date.accessioned2016-10-25T17:44:45Z-
dc.date.available2014-05-20T15:10:20Z-
dc.date.available2016-10-25T17:44:45Z-
dc.date.issued2005-10-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-40422005000500009-
dc.identifier.citationQuímica Nova. Sociedade Brasileira de Química, v. 28, n. 5, p. 783-787, 2005.-
dc.identifier.issn0100-4042-
dc.identifier.urihttp://hdl.handle.net/11449/27592-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/27592-
dc.description.abstractA simple flow injection procedure was developed for determining dipyrone (1-phenyl-2,3-dimethyl-4-methylaminomethano-5-pyrazolone sodium, metamizol, analgin) in pharmaceutical formulations. The determination is based on the reduction of Ag+ ions to Ag0 by dipyrone. A colloidal suspension of Ag0 produced was transported by carrier solution (0.01 mol L-1 NaOH) and turbidimetrically detected at 425 nm. The analytical curve for dipyrone was linear in the range from 5.0 x 10-4 to 2.5 x 10-3 mol L-1 with a correlation coefficient of 0.9990. The detection limit was 1.3 x 10-4 mol L-1 (3sigmaB/slope). The relative standard deviation for ten successive measurements was 1.8% and an analytical frequency of 45 h-1 was obtained. The recovery values from three samples ranged from 96.0 to 102%.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)-
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)-
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)-
dc.format.extent783-787-
dc.language.isopor-
dc.publisherSociedade Brasileira de Química-
dc.sourceSciELO-
dc.subjectdipyroneen
dc.subjectflow injection turbidimetryen
dc.subjectsolid-phase reactoren
dc.titleDeterminação turbidimétrica de dipirona em fluxo utilizando um reator contendo cloreto de prata imobilizado em resina poliésterpt
dc.title.alternativeFlow injection turbidimetric determination of dipyrone using a solid-phase reactor containing silver chloride immobilized in a polyester resinen
dc.typeoutro-
dc.contributor.institutionUniversidade Federal de São Carlos (UFSCar)-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUniversidade Federal de São Carlos (UFSCar) Centro de Ciências Exatas e de Tecnologia Departamento de Química-
dc.description.affiliationUniversidade Estadual Paulista-
dc.description.affiliationUnespUniversidade Estadual Paulista-
dc.identifier.doi10.1590/S0100-40422005000500009-
dc.identifier.scieloS0100-40422005000500009-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-40422005000500009.pdf-
dc.relation.ispartofQuímica Nova-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.