You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27910
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMatuo, T.-
dc.date.accessioned2014-05-20T15:11:08Z-
dc.date.accessioned2016-10-25T17:45:27Z-
dc.date.available2014-05-20T15:11:08Z-
dc.date.available2016-10-25T17:45:27Z-
dc.date.issued1984-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-83581984000200007-
dc.identifier.citationPlanta Daninha. Sociedade Brasileira da Ciência das Plantas Daninhas , v. 7, n. 2, p. 81-89, 1984.-
dc.identifier.issn0100-8358-
dc.identifier.urihttp://hdl.handle.net/11449/27910-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/27910-
dc.description.abstractFoi estudada a viabilidade de utilização da pulverização CDA 25C, na aplicação do herbicida em pré-emergência na cultura do arroz de sequeiro. O herbicida empregado foi o pendimethalin nas doses de 0,0; 1,5; 2,0; 2,5 e 3,0 litro s/ha da formulação comercial a 50%. A pulverização convencional foi efetuada com bicos 11003 com consumo de 200 litros de calda per hectare. O processo CDA 250 foi aplicado por meio de bico rotativo (Micromax) com dois níveis de consumo de calda : 50 1/ha e 27 1/ha. Os resultados mostraram que: a) - o método CDA 250 proporciona controle dc mato e produtividade de arroz equivalentes ao método convencional; b) para o bico Micromax, a aplicação da formulação comercial de pendimethalin a 50% com vazão de 0,48 1/min./bico, a distância entre bicos deve ser de 1,75 m e para a vazão de 0,96 1/min./bloco, essa distancia deve ser de 1,90 m; c)- a aplicação do pendimethalin 50% C.E. pelo processo CDA 250, empregando 27 litros de calda por hectare foi o processo mais interessante por oferecer vantagens logísticas apreciáveis.pt
dc.description.abstractThe feasibility of pre-emergenge herbicide application for upland rice by CDA 250 spray method was studied. The herbicide used was pen dimethalin at 0,0; 1,5; 2,0; 2,5 and 3,0 1/ha of comercial 50% E.C. formulation. Conventional spraying was carried out using 110C3 flat fan nozzles applying 200 1/ha of spray volume CDA250 was applied by rotary atomizers (Micromax) spraying twc volume rates: 50 1/ha and 27 1/ha. The results pointed out that: a)- CDA 250 spray method was equivalent to the conventional spray method in the control of weeds and crop yield; b) - for Micromax nozzles applying commercial 50 E.C. formulation of pendimethalin at 0,48 /min of nozzle feed rate, the distance between nozzles should be 1,75 m and at 0,96 1/min feed rate this distance shoud be 1,90 m; c)- CDA 250, applying 27 1/ha presents large logistic advantages.en
dc.format.extent81-89-
dc.language.isopor-
dc.publisherSociedade Brasileira da Ciência das Plantas Daninhas-
dc.sourceSciELO-
dc.subjectCDA 250pt
dc.subjectbico rotativopt
dc.subjectpulverizaçãopt
dc.subjectpendimethalinpt
dc.subjectCDA 250en
dc.subjectrotary atomizeren
dc.subjectsprayen
dc.subjectpendimethalinen
dc.titlePulverização em CDA 250 herbicida pendimethalin na cultura do arroz de sequeiropt
dc.title.alternativeApplication of pendimethalin with cda 250 spfayer for upland riceen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP FCAV-
dc.description.affiliationUnespUNESP FCAV-
dc.identifier.doi10.1590/S0100-83581984000200007-
dc.identifier.scieloS0100-83581984000200007-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-83581984000200007.pdf-
dc.relation.ispartofPlanta Daninha-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.