You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/27918
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMatuo, Tomás K.-
dc.contributor.authorMatuo, Tomomassa-
dc.date.accessioned2014-05-20T15:11:09Z-
dc.date.accessioned2016-10-25T17:45:29Z-
dc.date.available2014-05-20T15:11:09Z-
dc.date.available2016-10-25T17:45:29Z-
dc.date.issued1995-01-01-
dc.identifierhttp://dx.doi.org/10.1590/S0100-83581995000100004-
dc.identifier.citationPlanta Daninha. Sociedade Brasileira da Ciência das Plantas Daninhas , v. 13, n. 1, p. 22-25, 1995.-
dc.identifier.issn0100-8358-
dc.identifier.urihttp://hdl.handle.net/11449/27918-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/27918-
dc.description.abstractDurante a fase de desenvolvimento de novos produtos fitossanitários é comumente utilizado o pulverizador a pressão constante, pressurizado com CO2. O gás carbônico pode provocar a acidificação da água e afetar o comportamento do composto que está sendo avaliado. No presente trabalho, amostras de água de 30 diferentes fontes foram pressurizadas com CO2 durante cinco minutos, até 275 kPa (40 lbf/pol.2), e o pH foi medido na água que saiu do bico e na água no inteior do tanque do pulverizador. Os resultados mostraram redução nos valores do pH em toda as amostras . Os valores do pH elevaram-se ligeiramente após a saída da água pelo bico do pulverizador. A redução, em alguns casos, foi marcante, atingindo 4,91 unidades de pH no caso mais drástico. Esses dados levam a recomendar cautela na interpretação dos resultados obtidos com o uso dos pulverizadores pressurizados com o gás carbônico.pt
dc.description.abstractA constant pressure sprayer pressurized by CO2 is commonly used during the development of new pesticide compounds. CO2 may cause acidification of the water and thus affect the behavior of the compound being tested. In the present study samples of water from 30 different sources were pressurized to 275 kPa (40 psi) by CO2 during five minutes and the pH was measured in the water emerging from the nozzle and in that remaining in the sprayer tank. The results showd a market reduction of pH values in all samples after pressurization. The pH values rose slightly after emergence from the nozzle. The reduction in some cases was drastic, reaching 4.91 pH units in one of the samples. These findings suggest that the results of pesticide test that involved CO2 pressurized sprayers shoud be interpreted with caution.en
dc.format.extent22-25-
dc.language.isopor-
dc.publisherSociedade Brasileira da Ciência das Plantas Daninhas-
dc.sourceSciELO-
dc.subjectPluverizador de pressão constantept
dc.subjectteste de produtospt
dc.subjectherbicidaspt
dc.subjectacidez da águapt
dc.subjectConstant pressure sprayeren
dc.subjectpesticide trialsen
dc.subjectherbicidesen
dc.subjectwater acidityen
dc.titleEfeito da pressurização com CO2 sobre o pH da águapt
dc.title.alternativeEffect of CO2 pressurization on the water pHen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.description.affiliationUNESP FCA-
dc.description.affiliationUnespUNESP FCA-
dc.identifier.doi10.1590/S0100-83581995000100004-
dc.identifier.scieloS0100-83581995000100004-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0100-83581995000100004.pdf-
dc.relation.ispartofPlanta Daninha-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.