You are in the accessibility menu

Please use this identifier to cite or link to this item: http://acervodigital.unesp.br/handle/11449/28722
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCordeiro, Ricardo-
dc.contributor.authorLima Filho, Euclydes Custódio de-
dc.contributor.authorSalgado, Paulo Eduardo deToledo-
dc.date.accessioned2014-05-20T15:13:16Z-
dc.date.accessioned2016-10-25T17:47:18Z-
dc.date.available2014-05-20T15:13:16Z-
dc.date.available2016-10-25T17:47:18Z-
dc.date.issued1996-12-01-
dc.identifierhttp://dx.doi.org/10.1590/S0102-311X1996000400003-
dc.identifier.citationCadernos de Saúde Pública. Escola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz, v. 12, n. 4, p. 455-463, 1996.-
dc.identifier.issn0102-311X-
dc.identifier.urihttp://hdl.handle.net/11449/28722-
dc.identifier.urihttp://acervodigital.unesp.br/handle/11449/28722-
dc.description.abstractForam alocados aleatoriamente vinte trabalhadores expostos ocupacionalmente ao chumbo em uma indústria de acumuladores elétricos de médio porte, no interior do Estado de São Paulo, os quais apresentavam plumbemia e excreção urinária do ácido delta-aminolevulínico, nos últimos dois anos, sempre menores que 60 µg/dL e 10 mg/L, respectivamente. Os trabalhadores foram submetidos a eletroneurografia do nervo radial direito e a dosagem de plumbemia. Com estas medidas ajustou-se um modelo de regressão linear simples de primeira ordem, tendo como variável dependente a velocidade de condução e como variável independente a plumbemia. Analisando-se a regressão ajustada, infere-se que o valor preditivo negativo do limite de tolerância biológica brasileiro aplicado à plumbemia seja de apenas 0,63. O estudo sugere que o valor do referido limite de tolerância deva ser reduzido do atual valor de 60 µg/dL para 32 µg/dL, para ter um valor preditivo negativo de 0,99.pt
dc.description.abstractWe randomly selected twenty lead workers from an electric accumulator factory in the State of São Paulo, Brazil, whose blood lead level and urinary d-aminolevulinic acid level were below 60 mg/dL and 10 mg/L, respectively. The workers were submitted to a standard motor nerve conduction velocity study of the right radial nerves, in addition to blood lead dosage. Based on these measures, a first-order linear regression model was adjusted, where the dependent variable was conduction velocity and the independent variable was the blood lead level. Analyzing the fitted model, we inferred that the negative predictive value of the Brazilian biological exposure limit is 0.63. In order for the above biological exposure limit to have a negative predictive value of 0.99, the study suggests that it be reduced from its present value (60 mg/dL) to 32 mg/dL.en
dc.format.extent455-463-
dc.language.isopor-
dc.publisherEscola Nacional de Saúde Pública Sergio Arouca, Fundação Oswaldo Cruz-
dc.sourceSciELO-
dc.subjectChumbopt
dc.subjectIntoxicação por Chumbopt
dc.subjectDoenças Ocupacionaispt
dc.subjectSaúde do Trabalhadorpt
dc.subjectExposição Ambientalpt
dc.subjectLeaden
dc.subjectLead Poisoningsen
dc.subjectOccupational Diseasesen
dc.subjectWorker's Healthen
dc.subjectEnvironmental Exposureen
dc.titleReajustando o limite de tolerância biológica aplicado à plumbemia no Brasilpt
dc.title.alternativeReadjustment of the biological exposure limit applied to blood lead levels in Brazilen
dc.typeoutro-
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)-
dc.contributor.institutionEscola Nacional de Saúde Pública-
dc.description.affiliationUniversidade Estadual Paulista-
dc.description.affiliationEscola Nacional de Saúde Pública-
dc.description.affiliationUnespUniversidade Estadual Paulista-
dc.identifier.doi10.1590/S0102-311X1996000400003-
dc.identifier.scieloS0102-311X1996000400003-
dc.rights.accessRightsAcesso aberto-
dc.identifier.fileS0102-311X1996000400003.pdf-
dc.relation.ispartofCadernos de Saúde Pública-
Appears in Collections:Artigos, TCCs, Teses e Dissertações da Unesp

There are no files associated with this item.
 

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.